Télécharger Imprimer la page

GEZE GC 302 Mode D'emploi page 2

Publicité

Les langues disponibles

Les langues disponibles

EN ISO
9001
Remote conrol GC 302, GC 332,
Quality
international
Jupiter R, Presence S
level
Operating instructions
General
5 cm / 2''
1
Safety instructions
Caution: Do not point the IR beam towards your eyes! Observe the national and international regulations on door safety. Only trained, qualified person-
nel may mount and start up the sensors. The unit may only be opened and repaired by GEZE. Always consider the safety functions of your application as
a whole, never just in relation to one individual section of the system. The installer is responsible for carrying out a risk assessment and installing sensors
and door systems correctly.
2
Startup
Function
Switching on
Remote control
Press
Buzzer
Press
* After two minutes, the unit automatically switches itself off if no key is pressed.
4
Establishing connection
Remote control for the sensor functions bidirectionally. Benefit: Changes to the settings on the sensor are immediately signalled back by the sensor to the
remote control. The sensor has various configurations for special applications which can easily be set on the remote control. Please comply with the origi-
nal operating instructions for the corresponding sensor.
Note: The connection between the remote control and the sensor can only be established when the sensor is in configuration mode.
Configuration mode is activated when the sensor is switched on. For reasons of safety, this mode is exited again automatically 30 minutes after the last
setting has been made, and the connection between the remote control and the sensor is interrupted. The connection can be re-established by briefly
pressing a button on the sensor or briefly interrupting the electrical power supply to the sensor. In some sensor models, the connection can also be
re-established using the "access code" function on the remote control. Please refer to the operating instructions for the sensor that you are using in
order to find information about settings and correct operation.
Sensor scan mode
Press
for 2 seconds
5
AIR detector
6
Technical data
Operating temperature
Max. air humidity
Mat. no. 099583 mod. 05
Switching off*
for 2 seconds Press
for 2 seconds
for 2 seconds Press
for 2 seconds
Available addresses
5 cm
-20°C to 40°C
90%, non-condensing
Interface
Display
AIR detector
Numerical keys 1 to 9
Function keys A to F
Start / establishing the connection G
Battery compartment
Cover with compartment for short manuals
3
Operating statuses
Off
Status
Display
No AIR field detected
green
AIR field detected
red
Batteries
3 batteries, type Micro/AAA 1.5 V
Technology
Active infrared, 40 kHz
Bidirectional remote control
AIR detector for sensor setup
On
Lights green or red
Flashes green or red
Fully charged battery
Flat battery
Select address
Sensor flashes
Buzzer function
(if switched on, see «2. Startup»)
No buzzing
Constant buzzing
Operating instructions Jupiter R, Presence S

Publicité

loading

Ce manuel est également adapté pour:

Gc 332Jupiter rPresence s