8
2.5
RATING PLATE INFORMATION
For rating plate location, see
EN
"INSTALLATION OVERVIEW" section.
This illustration is for reference only.
Refer to the rating plate on the
appliance for accurate information.
NOTE: The rating plate must
remain with the appliance at all
times. It must not be removed.
W415-1468 / A / 09.30.16
LISTED SOLID FUEL BURNING SPACE HEATER / POÊLE À COMBUSTIBLE SOLIDE
HOMOLOGUÉ TESTED TO: / TESTÉ SELON : UL1482 / ULC S627
9700539 (WSL)
S4
1400
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
POUR INSTALLATION ET
INSTALL AND USE ONLY IN
UTILISATION CONFORM ÉMENT AUX
ACCORDANCE WITH THE
INSTRUCTIONS DU FABRICANT ET
MANUFACTURER'S
AUX CODES LOCAUX DU BÂTIMENT.
INSTRUCTIONS AND LOCAL
HAUTEUR DE PLAFOND MINIMAL
BUILDING CODES.
7PI (2,13m).
MINIMUM CEILING HEIGHT:
PROLONGEMENT
7FT (2.13m)
D'ÂTRE/PROTECTION DU
HEARTH EXTENSION /
PLANCHER COMBUSTIBLE: SI
COMBUSTIBLE FLOOR
INSTALL É SUR UN PLANCHER
PROTECTION: IF INSTALLED
COMBUSTIBLE, L'APPAREIL DOIT
ON A COMBUSTIBLE FLOOR,
ÊTRE PLAC É SUR UNE PLAQUE
UNIT MUST BE PLACED ON A
PROTECTRICE INCOMBUSTIBLE
NON-COMBUSTIBLE FLOOR
S'ÉTENDANT SUR 18" (455mm) À
PROTECTOR EXTENDING 18"
L'AVANT ET 8" (205mm) À L'ARRIÈRE
(455mm) IN FRONT AND 8"
ET SUR LES CÔTÉS.
(205mm) TO THE SIDES AND
TYPE DE CHIMNÉE: DIAMÈTRE
BACK.
MINIMAL DE 6" (152mm)
CHIMNEY TYPE: MINIMUM 6"
APPROUVÉE POUR USAGE
(152mm) DIAMETER
RÉSIDENTIEL. MAISON MOBILE
APPROVED RESIDENTIAL
EMPLOYEZ UNE CHEMINÉE
TYPE FOR MOBILE HOME USE
HOMOLOGUÉE ULC S629 AU
A CHIMNEY LISTED TO ULC
CANADA OU UL 103HT AUX
S629 IN CANADA OR UL 103HT
ÉTATS-UNIS.
IN THE USA.
RACCORD DE CHEMINÉE:
CHIMNEY CONNECTOR: 6"
DIAMÈTRE DE 6" (152mm) D'ACIER
(152mm) DIAMETER MINIMUM
DE CALIBRE 24 MINIMUM. 18"
24 GAUGE STEEL MINIMUM
(455mm) DE DÉGAGEMENT MINIMAL
CLEARANCE FROM
ENTRE LE RACCORD HORIZONTAL
HORIZONTAL CONNECTOR
ET LE PLAFOND.
AND CEILING 18" (455mm).
NE RIEN ENTREPOSER SOUS
DO NOT OBSTRUCT SPACE
L'APPAREIL.
UNDER HEATER.
DES MÉTHODES SPÉCIALES SONT
SPECIAL METHODS ARE
REQUISES LORSQU'UNE CHEMINÉE
REQUIRED WHEN PASSING A
TRAVERSE UN MUR OU UN
CHIMNEY THROUGH A WALL
PLAFOND. VOIR LES INSTRUC-
OR CEILING. SEE INSTRUC-
TIONS ET LES CODES DU
TIONS AND BUILDING CODES.
BÂTIMENT.
DO NOT CONNECT THIS UNIT
NE PAS RACCORDER À LA
TO A CHIMNEY FLUE SERVING
CHEMINÉE D'UN AUTRE APPAREIL.
ANOTHER APPLIANCE.
COMBUSTIBLE: POUR USAGE AVEC
FUEL: FOR USE WITH WOOD
LE BOIS SEULEMENT. N'UTILISEZ
ONLY. DO NOT USE GRATE OR
PAS DE CHENET OU NE
ELEVATE FIRE. BUILD WOOD
SURÉLEVEZ PAS LE BOIS.
FIRE DIRECTLY ON HEARTH.
PRÉPAREZ LE FEU DIRECTEMENT
WARNING: RISK OF SMOKE
SUR L'ÂTRE.
SPILLAGE. OPERATE ONLY
AVERTISSEMENT: RISQUE
WITH DOOR FULLY CLOSED.
D'ÉCHAPPEMENT DE FUMÉE. TENIR
REPLACE GLASS ONLY WITH
LA PORTE FERMÉE LORSQUE LE
CERAMIC GLASS.
POÊLE FONCTIONNE. REMPLACEZ
DO NOT OVERFIRE. IF
LA VITRE PAR UNE VITRE EN
HEATER OR CHIMNEY
CÉRAMIQUE SEULEMENT.
CONNECTORS GLOW, YOU
NE SURCHAUFFEZ PAS L'APPAREIL.
ARE OVERFIRING. INSPECT
SI L'APPAREIL OU LES RACCORDS
AND CLEAN CHIMNEY
ROUGEOIENT, L'APPAREIL
FREQUENTLY. UNDER
SURCHAUFEE. INSPECTEZ ET
CERTAIN CONDITIONS OF
NETTOYEZ LA CHEMINÉE
USE CREOSOTE BUILD-UP
FRÉQUEMMENT. DANS CERTAINES
MAY OCCUR RAPIDLY.
CONDITIONS, DES DÉPÔTS DE
OPTIONAL BLOWER KIT:
CRÉOSOTE PEUVENT SE FORMER
EP-62, 115V, 60HZ, 0.82AMP.
RAPIDEMENT.
ROUTE CORD AWAY FROM
SOUFFLERIE OPTIONNELLE: EP-62,
UNIT.
115V, 60HZ, 0,82A. TENEZ LE
DANGER: RISK OF
CORDON ÉLECTRIQUE LOIN DE
ELECTRICAL SHOCK.
L'APPAREIL.
DISCONNECT POWER
DANGER: RISQUE DE SECOUSSE
BEFORE SERVICING UNIT.
ÉLECTRIQUE. DÉBRANCHEZ AVANT
INSERT: INSTALL AND USE
DE PROCÉDER À L'ENTRETIEN.
ONLY IN SOLID FUEL
ENCASTRÉ: INSTALLEZ ET UTILISEZ
BURNING FIREPLACES. DO
SEULEMENT DANS UN FOYER À
NOT REMOVE BRICKS OR
COMBUSTIBLE SOLIDE. NE RETIREZ
MORTAR FROM SOLID FUEL
PAS DE MORTIER, NI BRIQUES DU
BURNING FIREPLACE.
FOYER À COMBUSTIBLE SOLIDE.
INSTALL WITH A POSITIVE
INSTALLEZ AVEC UNE GAINE
FLUE CONNECTOR AND
CONFORME ET UNE PLAQUE DE
FACEPLATE.
RECOUVREMENT.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
1400 SERIES RATING PLATE ILLUSTRATED
MODEL / MODÈLE - EPA 1400
1450
1400L
1402
CONTACT LOCAL BUILDING FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION IN YOUR AREA. MODEL 1400 IS SUITABLE FOR USE
IN MOBILE HOMES WHEN USED WITH OUTSIDE AIR INSTALLATION KIT (111KT).
A MINIMUM CLEARANCE OF 18" (457mm) TO THE CHIMNEY CONNECTOR MAY
BE REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
RENSEIGNEZ-VOUS AUPR ÈS DES AUTORITÉS LOCALES DU BÂTIMENT ET DU
SERVICE DES INCENDIES AU SUJET DES RESTRICTIONS ET DES INSPECTIONS
D'INSTALLATION DANS VOTRE RÉGION. LES MODÈLES 1400 PEUVENT ÊTRE
INSTALLÉS DANS UNE MAISON MOBILE SI INSTALLÉS CONJOINTEMENT AVEC UNE
PRISE D'AIR EXTÉRIEUR (111KT). UN DÉGAGEMENT MINIMAL DE 18" (457mm)
JUSQU'AU RACCORD DE LA CHEMINÉE PEUT ÊTRE EXIGÉ PAR L'AUTORITÉ AYANT
JURIDICTION.
BACK WALL (M/A)
BACK WALL (M/A)
B
45°
A
C
ALCOVE
IF THE STOVE IS TO BE INSTALLED ON A COMBUSTIBLE FLOOR, IT MUST BE
PLACED ON AN APPROVED NON-COMBUSTIBLE HEARTH PAD, THAT
EXTENDS 8" (200mm) BEYOND THE STOVE SIDES AND BACK, AND 18"
(455mm) TO THE FRONT.
SI LE PO Ê LE EST INSTALL É SUR UN PLANCHER COMBUSTIBLE, IL DOIT ÊTRE PLACÉ
SUR UNE BASE DE PROTECTION INCOMBUSTIBLE CERTIFÉE QUI DOIT DÉPASSER
LES CÔTÉS ET L'AMÉRE DU PO Ê LE DE 8" (200mm) ET SE PROLONGER DE 18"
(455mm) SUR LE DEVANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL WITH SINGLE WALL
CHIMNEY CONNECTOR / D ÉGAGEMENTS MINIMAUX AUX MATÉRIAUX
COMBUSTIBLES AVEC RACCORD DE CHEMINÉE À PAROI SIMPLE:
FROM HEATER / DU POÊLE
RESIDENTIAL / RÉSIDENTIEL
1400
S4
12IN/PO (305 mm)
12IN/PO (305 mm)
16IN/PO (406 mm)
12IN/PO (305 mm)
6IN/PO (152 mm)
6IN/PO (152 mm)
USING DOUBLE WALL CONNECTOR /
MAISON / MOBILE HOME*
UTILISATION D'UN CONDUIT DE
RACCORDEMENT À DOUBLE PAROI
1400
1400
S4
10IN/PO (254 mm)
10IN/PO (254 mm)
16IN/PO (406 mm)
6IN/PO (152 mm)
6IN/PO (152 mm)
6IN/PO (152 mm)
4IN/PO (102 mm)
4IN/PO (102 mm)
4IN/PO (102 mm)
*
MODELS 1400 AND S4 MAY BE INSTALLED INTO A MOBILE HOME IN THE
UNITED STATES ONLY.
*
LE MODÈLES 1400 ET S4 NE PEUT ÊTRE INSTALLÉ QUE DANS UNE MAISON
MOBILE AUX ÉTATS-UNIS SEULEMENT.
THIS WOOD APPLIANCE NEEDS PERIODIC INSPECTION AND REPAIR FOR
PROPER OPERATION. CONSULT THE OWNER'S MANUAL FOR FURTHER
INFORMATION. IT IS AGAINST UNITED STATES FEDERAL REGULATIONS TO
OPERATE THIS WOOD APPLIANCE IN A MANNER INCONSISTENT WITH THE
OPERATING INSTRUCTIONS IN THE OWNER'S MANUAL.
CET APPAREIL AU BOIS DOIT FAIRE L'OBJECT D'UNE INSPECTION ET D'UN
ENTRETIEN PÉRIODIQUES POUR UN FONCTIONNEMENT ADÉQUAT. CONSULTEZ
LE MANUEL D'INSTRUCTIONS POUR PLUS D'INFORMATION. LES RÈGLEMENTS
FÉDÉRAUX DE L'ÉTATS-UNIS INTERDISENT D'UTILISER CET APPAREIL DE
CHAUFFAGE D'UNE MANIÈRE ALLANT À L'ENCONTRE DES INSTRUCTIONS DE
FONCTIONNEMENT CONTENUES DANS CE MANUEL.
LISTED SOLID FUEL BURNING FIREPLACE INSERT /
ENCASTRÉ À COMBUSTIBLE SOLIDE HOMOLOGUÉ
TESTED TO / TESTÉ SELON :
ULC S628 / UL 1482
CLEARANCES TO COMBUSTIBLE CONSTRUCTION /
D ÉGAGEMENTS AUX MATÉRIAUX COMBUSTIBLES:
(MEASURED TO UNIT / À PARTIR DE L'APPAREIL)
CEILING / PLAFOND
A SIDE FACING / CÔTÉ
D
C
B TOP FACING / DESSUS
B
C MANTEL / TABLETTE
A
D SIDE WALL / MUR LATÉRAL
FLOOR / PLANCHER
*
CLEARANCE TO EDGE OF FLASHING / DÉGAGEMENT AU
BORD DE LA FAÇADE
EPA1400
1400C
8"
B"
8"
8"
A"
18"
S4
16IN/PO (406 mm)
6IN/PO (152 mm)
4IN/PO (102mm)
EPI 1402
*
1 IN/PO (25mm)
28 IN/PO (710mm)
28 IN/PO (710mm)
17 IN/PO (430mm)
W385-2031 / A