Important Safety Instruction; Installation Instructions - Cardin ELDOM6 Serie Mode D'emploi

Barrière levante électromécanique avec moteur dc
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

READING THESE INSTRUCTIONS IS IMPORTANT FOR PERSONAL SAFETY. READ THE FOLLOWING REMARKS
CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO ALL THE PARA-
GRAPHS MARKED WITH THE SYMBOL
IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM AND
CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM. SAVE THESE INSTRUCTIONS FOR FUTURE USE.
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has expired
it must be disposed of separately from other rubbish. The user is
therefore obliged to either take the product to a suitable differen-
tial collection site for electronic and electrical goods or to send it
back to the manufacturer if the intention is to replace it with a new
equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal
contributes to avoiding negative effects on the ambient and consequently
health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and will be
dealt with according to the laws and standards of the individual member nation.
• These instructions are aimed at professionally qualified "Installers of electrical
equipment" and must respect the local standards and regulations in force.
All materials used must be approved and must suit the environment in which the
installation is situated.
• All maintenance operations must be carried out by professionally qualified techni-
cians. Before carrying out any cleaning or maintenance operations make sure the
power is disconnected at the mains and that the 24V battery supply connection
J1 has been disconnected.
• This appliance must be used exclusively for the purpose for which it has
been made. "i.e. for traffic control" of passageways with widths of 6 m.
Attention! The appliance has a total weight of about 80 kg therefore you
must use mechanical lifting equipment when transporting or installing.
• The unit may be fitted both to the right and to the left of the passageway.
• This product and all its relative components has been designed and manufac-
tured by Cardin Elettronica who have verified that the product conforms in every
aspect to the safety standards in force. Any non authorised modifications are to
be considered improper and therefore dangerous.
The manufacturer accepts no liability for situations arising from the use of an
electrical installation which does not conform to the local standards and regula-
tions in force and in particular when the earthing circuit is not efficient.

IMPORTANT SAFETY INSTRUCTION

It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the barrier installation is far enough away from the main road to eliminate
possible traffic disruptions.
2) The barrier must be installed on the inside of the property and not on the public
side of the property. The booms must not swing outwards onto a public area.
3) The barrier is designed for use on installations through which vehicles are passing.
Pedestrians should use a separate entrance.
4) The boom must be in full view when it is operating therefore controls must be
situated in a position where the operator can see the boom at all times.
5) At least two warning signs (similar to the example on the right) should
be placed, where they can be easily seen by the public, in the area of
the system of automatic operation. One inside the property and one
on the public side of the installation. These signs must be indelible
and not hidden by any objects (such as tree branches, decorative
fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must
not be allowed to play within the area of a road barrier installation.
Do not allow children to play with fixed controls and keep remote controls away
from them. This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or lack of experi-
ence and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
7) A correct earth connection is fundamental in order to guarantee the electrical safety
of the machine.
9) Before installing make sure that the ambient temperature falls within the range
indicated on the appliance's data plate.
9) If you have any questions about the safety of the boom operating system, do not
install the operator. Contact your dealer for technical assistance.
Have the appliance controlled and checked at regular intervals by specialised main-
tenance personnel:
- Check to be carried out after the first 200.000 manoeuvres (or six months after
the installation);
Periodically check the correct operation of all safety devices (photoelectric cells etc.).
Frequently examine the installation for imbalance where applicable and signs of wear
or damage to cables, springs and mounting.
ATTENTION! IMPORTANT SAFETY INSTRUCTIONS
IN THIS ORIGINAL INSTRUCTION MANUAL. NOT READING THESE
WARNING
AUTOMATIC OPENING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
Eventual repair work or maintenance must be carried out by specialised personnel
using original spare parts. The appliance is not suitable for continuous operation
and must be adjusted according to the model (see technical data on page 48).
TECHNICAL DESCRIPTION
ELDOM6DG
Automation for 6 m booms with a 24 Vdc motor.
Barrier cabinet with key lock, complete with boom support and LED flashing light
built into the head of the structure plus mechanical release accessible with key
from the outside
The incorporated electronic programmer contains the power stage, the logic control,
the battery charger and the radio receiver module. The power supply is routed to the
electronics card via a separate transformer which is housed in the same container.
DOM6
Extruded aluminium boom with paint finish, 6 metres long, complete with PVC
profiles.
DOM6L
Extruded aluminium boom with paint finish, 6 metres long, complete with LED
lights and PVC profiles.
BOXDOM
Accessory box with DIN rails and fixing plates
ELUFS1
Fixed aluminium support fork
BASEDOM68
Ground fastening base
• 24 Vdc motor with tempered steel never ending screws;
- lockable flip-back upper hood in spray-painted aluminium with built-in warning
lights;
- external manual release mechanism with key access;
- irreversible second stage reduction unit with tempered steel gears and first
stage reduction worm gear in highly reliable self-lubricating POM, mounted on
a cast aluminium stator;
- boom balancing spring;
- lubrication using permanently fluid grease;
- barrier cabinet made of spray-painted metal (cataphoresis passivation + powder
spray painting)

INSTALLATION INSTRUCTIONS

The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed in a location not accessible to children.
During the opening/closing manoeuvre check for correct operation and activate
the emergency stop button in case of danger.
During blackouts the boom can be released and manually manoeuvred (see
manual manoeuvre pag. 18).
• The ground must be stable enough to firmly hold the plinth and the anchor
plates.
• Where possible protect the barrier cabinet from accidental knocks by
passing vehicles.
• Work out the run of the cables according to the command and control
devices fitted and make sure the system conforms to the local standard
and regulations in force (see installation example fig. 1 pag. 2).
It is very important that the barrier be well fixed to the fastening base
as the ground anchors could loosen throughout time due to movement
and vibration and cause damage to the cabinet.
FITTING THE UNIT (fig. 3-3a)
Prepare a cement base with the base plate and anchors "C" (optional) embed-
ded. The cable passage pipe "D" and the four threaded bolts M12 must
protrude (30 mm) from the base plate.
The base plate must be perfectly in square, its surface must be clean
and the four threaded bolts must emerge perpendicularly.
Note: the cement base "A" should preferably protrude 50 mm out of the
ground in order to avoid water build up which could damage the appli-
ance. The size of the base plinth "B" will vary according to the characteristics
of the ground.
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Eldom6dg