PROGRAMMING PROCEDURE (parameter setting)
• All the functions of the electronic programmer can be set in the Display menu "LCD1" using the three buttons contained therein:
- use the arrows to navigate through the menu and/or to adjust the display contrast;
- use "PROG/OK" to modify the parameter settings and/or to confirm.
PROGRAM
OPTIONS
TB FI
TA TD
SAFETY DEVICES
FS CP
TC
MOTION
DISPLAY
CALENDAR
00.000.007
REMOTE
07-06-13 15.35
Press an arrow
SEQUENTIAL COM.
key to enter the
OPEN-SHUT/
main menu
OPEN-STOP-SHUT
AUTO. RECLOSING
The number of
ON/OFF
PRE-FLASHING
manoeuvres
ON/OFF
carried out by
the barrier and
the time and
SEQUENTIAL COM.
date are
OPEN-SHUT/
OPEN-STOP-SHUT
always shown
AUTO. RECLOSING
on the opening
ON/OFF
PRE-FLASHING
screen of the
ON/OFF
display.
SEQUENTIAL COM.
The plug
OPEN-SHUT/
symbol
OPEN-STOP-SHUT
AUTO. RECLOSING
indicates that the
ON/OFF
ECU is working
PRE-FLASHING
ON/OFF
off mains power.
AUTO. RECLOSING
The fully
ON/OFF
charged battery
PRE-FLASHING
ON/OFF
symbol
WARNING LIGHTS
indicates that the
FIXED/
INTERMITTENT
ECU is working
off battery power
at 100%.
PRE-FLASHING
ON/OFF
75%
WARNING LIGHTS
FIXED/
50%
INTERMITTENT
BOOM LIGHTS
25%
FIXED/
INTERMITTENT
0%
WARNING LIGHTS
FIXED/
INTERMITTENT
BOOM LIGHTS
"PROG/OK"
FIXED/
to change
INTERMITTENT
the value
PHOTOCELL INVERT
DURING CLOSING/
Note: 1
AND IN STOP
BOOM LIGHTS
FIXED/
INTERMITTENT
"PROG/OK"
PHOTOCELL INVERT
to change
DURING CLOSING/
the value
AND IN STOP
TEST FI
Note: 2
ON/OFF
PHOTOCELL INVERT
DURING CLOSING/
AND IN STOP
"PROG/OK"
TEST FI
to change
ON/OFF
the value
TEST FS
ON/OFF
TEST FI
ON/OFF
TEST FS
"PROG/OK"
ON/OFF
to change
the value
INSTALLED BOOM
LEFT
TEST FS
ON/OFF
"PROG/OK"
to change
INSTALLED BOOM
the value
LEFT/RIGHT
MEMO RADIO
ON/OFF
INSTALLED BOOM
"PROG/OK"
LEFT/RIGHT
to change
MEMO RADIO
the value
ON/OFF
ERR 230V BOOM UP
Note: 3
ON/OFF
MEMORADIO
ON/OFF
"PROG/OK"
ERR 230V BOOM UP
to change
the value
ON/OFF
RAPID RECLOSING
Note: 4
ON/OFF
OPTIONS
SAFETY DEVICES
MOTION
Arrow
Arrow
DISPLAY
to scroll
to scroll
CALENDAR
REMOTE
"PROG/OK"
"PROG/OK"
to confirm
to confirm
CONTACT TB
NC/8K2
CONTACT FI
"PROG/OK"
"PROG/OK"
"PROG/OK"
NC/8K2
to change
to change
to change
CONTACT FS
the value
the value
the value
NC/8K2
CONTACT TB
NC/8K2
"PROG/OK"
"PROG/OK"
"PROG/OK"
CONTACT FI
to change
to change
to change
NC/8K2
the value
the value
the value
CONTACT FS
NC/8K2
CONTACT TB
NC/8K2
"PROG/OK"
"PROG/OK"
"PROG/OK"
CONTACT FI
to change
to change
to change
NC/8K2
the value
the value
the value
CONTACT FS
NC/8K2
CONTACT FI
NC/8K2
"PROG/OK"
"PROG/OK"
"PROG/OK"
CONTACT FS
to change
to change
to change
NC/8K2
the value
the value
the value
CONTACT CP
NC/8K2
CONTACT FS
"PROG/OK"
NC/8K2
to change
CONTACT CP
the value
NC/8K2
EXIT
"PROG/OK"
to return to
'safety devices'
Note: 9
Note: 10
ERR 230V BOOM UP
"PROG/OK"
ON/OFF
to change
RAPID RECLOSING
the value
ON/OFF
Note: 5
AUX1 - AUX2
CH2 / CRTY LIGHT
RAPID RECLOSING
ON/OFF
AUX1 - AUX2
CH2 / CRTY LIGHT
"PROG/OK"
to return to
EXIT
'options'
OPTIONS
SAFETY DEVICES
MOTION
Arrow
DISPLAY
to scroll
CALENDAR
REMOTE
"PROG/OK"
to confirm
MOTOR SELECTION
ELDOM24 3/4M-6M
CURRENT SENSOR
LEVEL 1...5
LIMITED OPENING
SETTING 1...9
MOTOR SELECTION
ELDOM24 3/4M-6M
Note: 6
CURRENT SENSOR
"PROG/OK"
LEVEL 1...5
to change
BRAKING CLOSING
the value
SETTING 1...9
MOTOR SELECTION
ELDOM24 3/4M-6M
"PROG/OK"
CURRENT SENSOR
to change
LEVEL 1...5
the value
CLOSING BRAKING
Note: 7
SETTING 1...9
CURRENT SENSOR
LEVEL 1...5
"PROG/OK"
CLOSING BRAKING
to change
SETTING 1...9
the value
CLOSING DECELER.
Note: 8
SETTING 1...9
DIST. FROM OPEN
CLOSING BRAKING
STEPS 1...9
SETTING 1...9
CLOSING SPEED
CLOSING DECELER.
LEVEL 1...3
SETTING 1...9
PAUSE TIME
OPENING DECELER.
130 SEC.
SETTING 1...9
CLOSING SPEED
CLOSING DECELER.
LEVEL 1...3
SETTING 1...9
PAUSE TIME
OPENING DECELER.
180 SEC.
SETTING 1...9
DIST. FROM CLOSE
RESET PARAMETERS
STEPS 1...9
PAUSE TIME
SLOWING IN OPENING
SETTING 1...9
180 SEC.
DIST. FROM CLOSE
RESET PARAMETERS
STEPS 1...9
DIST. FROM OPEN
FW VERSION
STEPS 1...9
ELDOM24 V0.04
DIST. FROM CLOSE
RESET PARAMETERS
STEPS 1...9
FW VERSION
DIST. FROM OPEN
ELDOM24 V0.04
STEPS 1...9
CLOSING SPEED
LEVEL 1...3
Notes:
1) FI Mode:
-
FI also active when the boom is blocked: If the photocells are in alarm and the
boom is blocked, no movement commands will be accepted (even opening
commands);
-
FI active only during closing
In both cases activating the FI safety device during the closing stage will force
travel direction inversion.
2) Photocell test (FI/FS)
If you enable the security test you will have to connect both the transmitter and
the receiver to the controlled load output (CTRL 24 Vdc). When the test is enabled
one second will pass between receiving a command and carrying it out.
3)
Errore linea 230V
In caso di interruzione dell'alimentazione elettrica 230V l'asta si aprirà completa-
mente (90°). Al ripristino dell'alimentazione 230V l'asta si richiude se la richiusura
automatica è inserita.
4) Fast closing
OFF = function deactivated - ON = type 1 - ON = type 2:
When the fast closing function is active, closing is determined by the beam
of the photocells FI being broken (or obviously by activation of a TC control);
the programmed pause time is therefore ignored.
20
OPTIONS
SAFETY DEVICES
MOTION
DISPLAY
CALENDAR
REMOTE
"PROG/OK"
to confirm
CONTRAST
0....63
REAR LIGHTING
"PROG/OK"
to confirm
ALWAYS ON/60/30 SEC.
EXIT
CONTRAST
0....63
"PROG/OK"
REAR LIGHTING
to change
ALWAYS ON/60/30 SEC.
the value
EXIT
CONTRAST
0....63
REAR LIGHTING
ALWAYS ON/60/30 SEC.
EXIT
"PROG/OK"
to return to
'display'
Press the arrows
to increase or
decrease the value
(max. 240 seconds).
Keeping the arrows
held down will force
the value to scroll
rapidly.
* * * * * * * * * * * * * * *
*
"PROG/OK"
*
PAUSE TIME
to confirm
*
180
*
* * * * * * * * * * * * * * *
"PROG/OK"
to confirm
OK.
OK
"PROG/OK"
OK
per ritornare al
menu moto
EXIT
* * * * * * * * * * * * * * *
*
*
* SET CONTRAST *
SEC.
26
*
*
*
*
* * * * * * * * * * * * * * *
Press the arrows
to increase or
decrease the value
(max. 63)
*
*
SEC.
*
*