Terminal board connections
1-2
MOT motor power supply (to change the sense of rotation select RIGHT or
LEFT boom installation from the OPTIONS menu)
3-4 ENCODER inputs Bl-Gr for the encoder signal
ENCODER inputs Gy-Yw for the encoder signal
5-6
7
LCK
8-9
EMRG Emergency stop button
10-11 AUX1 Potential free NO-contact indicating the status of the boom (separate power
supply Vmax=30 Vac/dc: Imax=1A) or the second radio channel. Selection is
carried out on the display LCD1.
12-13 AUX2 Potential free NO-contact indicating the status of the boom (separate
power supply Vmax=30 Vac/dc: Imax=1A) or for the activation of the courtesy
light. Selection is carried out on the display LCD1.
14
CMN common for all inputs and outputs
15
LP 24 Vdc 25 W output for warning lights intermittent activation (50%),
12,5 W continuous activation
16
LED 24 Vdc 3 W output for the boom lights (pre-wired)
CMN common for all inputs and outputs
17
24 Vdc controlled output, powering external loads
18
19
CMN common for all inputs and outputs
20
24 Vdc output, powering external loads
21
TA1 (N.O. contact) opening button 1 input
22
TA2 (N.O. contact) opening button 2 input
23
TC1 (N.O. contact) closing button 1 input
TC2 (N.O. contact) closing button 2 input
24
CMN common for all inputs and outputs
25
26
TB (N.C./8.2 kΩ) stop button input (The opening of this contact interrupts the
cycle until a new movement command is given)
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
27
CP (N.C./8.2 kΩ) safety edge input. Opening this contact will provoke a travel
direction inversion of a few degrees during the closing stage and during the
opening stage
(2)
FS (N.C./8.2 kΩ) The opening of this contact will block all movement, until the
28
obstruction has been removed and the pause time has elapsed, due to the safety
device cutting in, the door will then continue moving in the closing direction (only
with automatic reclosing enabled)
29
FI (N.C./8.2 kΩ) safety and control devices in input (photocells invert the travel
direction when an obstruction is detected). Opening this contact will provoke a
travel direction inversion during closure due to the cutting in of the safety device
31
Mass conductor for radio receiver antenna
30
Pole conductor for radio receiver antenna (if an external antenna is fitted use a
coaxial type cable RG58 with an impedance of 50Ω)
CS 1470B
15A
DC 0551
J1
F3
L2
F2
4A
J2
F1
15A
8
9
10
B1
Signal buzzer "via radio" mode
BC
Battery charger card
LCD1
Display
F1
15A blade fuse
(motor power protection)
(4)
F2
4A blade fuse
(24V circuit protection)
(4)
F3
15A blade fuse
(motor protection during battery operation)
(4)
F4
4A blade fuse
(24V circuit protection during battery operation
(4)
Nota
(4)
These are automotive type blade fuses (max. voltage
(1)
(1)
(2)
(2)
4A
F4
L1
11
12
13
14
15
16
17
18
58V)
32
CMN common for the emergency buttons
EMRG1 (N.A.) ingresso pulsante per manovra di emergenza 1
33
EMRG2 (N.A.) ingresso pulsante per manovra di emergenza 2
34
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the correspond-
ing security device tests (FI, FS) must also be deactivated. If you want to activate the
FI, FS test both the transmission and receiver parts of the security devices must be
connected to the binding post marked (CTRL24Vdc).
If the test is active there will be a 1 second delay between the command transmission
and movement of the boom.
• Switch on the power and make sure that
the indicator LEDs are in the following condition.
- L1 Power on
- L2 Wrong battery connection
Indications on the display
- S1 Indicator for the blocking button
- S2 Indicator for the inverting photoelectric cells
- S3 Indicator for the stop photoelectric cells
- S4 Indicator for the safety edge
- S5 Indicator for the opening button
- S6 Indicator for the closing button
- S7 Indicator for the sequential command
If the green power on LED "L1" doesn't light up check the condition of the fuses
and the power cable connection at the transformer primary.
If one or more of the safety indications "S1, S2, S3, S4" flash check the con-
tacts of the relative security devices and check that the unused safety device
contacts have been bridged.
The indications "S5, S6, S7" change status on the display when the relative
command is activated, eg. pressing the button "TA" will change the status from
'at rest' to 'active'
(white characters on a black background).
Note
The total of the 2 external device outputs must not exceed 10W.
(1)
Note
The (N.C./8.2 kΩ) selection is carried out on the LCD1 display.
(2)
Note
(3)
If this LED is "ON" invert the battery power cables immediately.
(2)
Note
If the security device has not been activated the indications on the display
(4)
are at rest. Make sure that when the security device is activated the
status is inverted (black characters on a white background).
BC
B1
24
19
20
21
22
23
25
J1
Battery connection
J2
Transformer secondary protection
J3
Emergency enable jumper
MM
Transmitter code memory module
P1
Menu navigation button (
P2
Programming and confirm button (PROG./OK)
)
P3
Menu navigation button (
R1
Radio frequency module, 433 MHz for series S4XX and S500 transmitters
19
S1
S3
ON
00.000.007
(3)
OFF
07-06-13
at rest activated
TB
FS
CP
TA
TC
TD
TB FI
FS CP
00.000.007
07-06-13
P1
MM
MM
R1
32
27
28
29
30
31
26
)
)
S5
S2
S7
TB FI
TA TD
FS CP
TC
S4
S6
15.35
(4)
TB
FI
(4)
FI
(4)
FS
(4)
CP
TA
TC
TD
LCD1
PROGRAM
TA TD
TC
15.35
P2
P3
J3
1 2
1 2
3
3
Pos.1 Pos.2
Disable
J3
33
34
Enable