INSTALLATION GUIDELINES
The UV-C LEDs are sensitive to dirt and oils. Wear gloves during installation and do not touch the LEDs. Touching the
LEDs could result in reduced LED life.
To prevent UV overexposure, install the fan so that the airfoils are a minimum of 10 ft (3.05 m) above the fl oor, and
ensure there are no open sightlines between the UV-C light and exposed upper fl oors, stairs, or walkways.
Highest Irradiance at 500 mm: 58.0 uW/cm^2
< 10 ft
(< 3.05 m)
HARDWARE
x2
8-32 x 5/8" Pan Head Screws
1. FAN
New Fan Installation: Install the fan according to the Quick Installation Guide. Do not install the extension tube cover
plate provided with the fan (step 4). Do not connect the wall controller wiring (step 7) or fi re relay wiring (step 8).
Discard the RJ45 adapter cable shown in the wall controller wiring diagram.
Fan Already Installed: Remove and discard the extension tube cover plate and hardware. Disconnect all wall
controller and fi re relay wiring from the low voltage junction box. Discard the wall controller RJ45 adapter cable.
≥ 10 ft
(≥ 3.05 m)
x2
10-32 x 5/16" Set Screws
x2
8-32 x 3/4" Flat Head Screws