Thermostats - L.B. White Guardian AD/AW060 Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12
Guardian LP or Natural Gas Heater
Manual Shut-off Valve,
Hose & Regular Assembly
(Must be ordered separately)
1. Always use approved pipe thread compound suitable
for use with L.P. gas or natural gas on the threaded
connections.
2. Assemble the components together according to Fig.
5. This view is to show general assembly of the com-
ponents only. The regulator must always be mounted
so its vent, regardless of location on the regulator, is
always pointed downward.
Note: Regulators located in doors should be vented
back to outdoors. Refer to NFPA54, National Fuel
Gas Code Handbook, CAN-B1491, CAN-B149,2,
& local codes as appropriate.
3. Tighten all connections securely.
4. Check all connections for gas leaks us-
ing approved gas leak detectors.
FIG. 5
REGULATOR VENT
TO CONTROL
VALVE INLET
Owner's Manual • Guardian

Thermostats

(Must be ordered separately)
■ Disconnect the electrical supply before
■ Failure to follow this warning can result in
1. To Connect the Series Tap Plug
2. To Connect the Direct Wired
REGULATOR
NIPPLE
VALVE, MANUAL
SHUT-OFF
GAS HOSE
ADAPTER
SEDIMENT TRAP
WARNING
Electrical Shock Hazard
connecting the thermostat to the heater.
electrical shock, leading to personal injury
or death.
Thermostat Kit:
a. Connect the power cord of the heater to the
female side of the plug on the end of the kit's
thermostat cord.
b. Plug the male side of the series tap plug on the
kit's thermostat cord into a three-wire (grounded)
electrical outlet.
Thermostat Kit to the Control
Box on the Heater:
a. Open the control box.
b. Remove the yellow wire connected between the
24 volt output of the transformer and terminal W of
the ignition control.
c. Remove the plastic hole plug at the back or bottom
of the control box. Run the wiring of the thermostat
kit through this hole.
d. Connect the black lead of the thermostat kit to the
24 volt output terminal of the transformer.
e. Connect the white lead of the thermostat kit to
terminal W of the igntion control.
f. Install the strain relief (supplied on thermostat
cordset) around the cord at the entry hole of the
control box.
g. Close and latch the control box.
h. Start the heater and check for proper
operation.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Guardian ad/aw100Guardian ad/aw250Guardian aw325Guardian aw060Guardian aw100Guardian aw250 ... Afficher tout

Table des Matières