Télécharger Imprimer la page

Rocal G 505 Manuel D'installation Et De Fonctionnement page 18

Publicité

Les langues disponibles

Les langues disponibles

2. USER'S GUIDE
ALL LOCAL REGULATIONS, INCLUDING THE ONES ACCORDING TO THE
NATIONAL OR EUROPEAN NORMS MUST BE ACCOMPLISHED WHEN
PROCEEDING TO INSTALL THE FIREPLACE.
Warning: Do not operate or handle any part when the fireplace is working
unless using the exothermic glove.
ATTENTION:
You must respect the maximum load allowed by the manufacturer of the logs as well as
the height of the recharge.
2.1. Using for the first time. For early on, and for a reasonable time, the fuel load
should not exceed 50% C.M.A. (Maximum fuel load authorised by the
manufacturer).
2.2. Fire control. In order to get the performance and power of the value table,
you must follow the position settings in the table of Technical characteristics.
2.2.1. Primary register (C21). Is located on the left side of the appliance. This
register is used only for power, or aid in a lean burn (this record is identified with a
flame of fire).
2.2.2. Secondary register (C22). Is located on the right side of the apparatus.
Serves for adjusting and maintaining the intensity of combustion.
Must avoid an excessive combustion and excess temperature in the combustion
chamber. One symptom of this excess of temperature is the whitening of the
glass.
Keep in mind that the registration is closed secondary, more dirt is embedded in
the glass. Moving up and down activates these registrer.
ATTENTION:
The positions indicated are according to technical characteristics table, in any
case these positions must be adapt according to the flue depression and fuel
quality.
2.3. Safety distances. Appliances, furniture and other flammable or breakable
items (textiles, electronics, wood, wallpaper, glass, chalk paper, etc..) must not
approach any point of the product it is seen, and bear in mind that the outputs hot
air cannot be objects or flammable items without safety distances described in the
Technical characteristics
2.4. Fire types. This apparatus is an on and off fire. The smoke chamber must be
closed except when being loaded, to avoid any smoke out fuel debris. It is
convenient when loading the fireplace, to avoid any leak or smoke escape.
2.5. Authorized fuel.
The appliance should not be used as an incinerator and
other fuels that are forbidden by the manufacturer's authorized. As fuel only use
natural wood logs is not advisable to use resinous wood is allowed.
Página 18 de 33

Publicité

loading

Ce manuel est également adapté pour:

M1755