in case the recess has a depth lower than 380
mm., cut the threaded bars supplied with the
appliance.
For SLT952 model, with internal motor, use
the 300mm long threaded bars provided for
the suctioning unit; threaded bars are inten-
ded to install the cooker hood at a distance of
450mm from the solid ceiling.
In case of a wider distance between the cei-
ling-mounted cooker hood and the ceiling,
use longer threaded bars .
Make the electrical connection and connect
the air out-let pipe; place the ceiling-moun-
ted cooker hood into the recess, inserting
the threaded bars into the holes (Fig. 6); the
outer edge of the cooker hood needs to be
perfectly flush with the false ceiling. Insert
the plates and the nuts provided into the
threaded bars, making sure to tighten them
securely (fig. 7); refit the grease filters into
their seating and close the panels.
WORKING
6 - channel radio control for cooker hood re-
mote (fig. 10).
Technical data:
Alkaline battery powered: 12v mod. 23A
Operating frequency: 433.92 Mhz
Combinations: 4096
Max. consumption: 25mA
Operating temperature: -20° : +55°C
- To light the cooker hood on or to
light it off press the button:
- To increase the speed up to the
fourth one press the button:
- To reduce the speed up to the
second one press the button:
- To go from a high speed back to
the first one press twice the button:
- To give power to the lights or to
shut them down press the button:
The "light" switch can turn the lights on and
off. after the first touch of the light switch the
lamps turn on at the maximum power. Kee-
ping the switch pressed the intensity of the
light decreases and then increases continuo-
usly. Leaving the switch the brightness re-
mains set up. Touching again the light switch
it is possible to turn the lamps off.
- To set the timer up press the
button:
The LED on the right side will start to flash
(every 5 seconds), the hood will work for 10
minutes at the selected speed and then it li-
ghts automatically off. If the client increases
or reduces the speed while the timer is on,
this is automatically stopped.