THERMO TECHNICAL CHARACTERISTICS according to EN 14785
Heat output
Yield / Efficiency
Emissions CO 13% O
2
Fume temperature
Fuel consumption
Draught
Hopper capacity
Autonomy
Heatable volume *
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
Weight including packaging (Sally steel-ceramic/Sally Plus steel-ceramic)
TECHNICAL DATA FOR THE DIMENSIONING OF THE FLUE
Temperature of fumes on exit from the discharge pipe
Minimum draught
Fume flow capacity
* The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.

ELECTRICAL CHARACTERISTICS

Power supply
On/off switch (see page 27)
Average power consumption
Power consumption during ignition
Remote control frequency
Protection on mains power supply* (see page 20)
Protection on electronic circuit board
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by qualified personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
The above data are indicative and are those resulting during certification on the part of the notified body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.

SAFETY DEVICES

• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on defined parameters.
• VACUUM GAUGE:
Positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber.
• SAFETY THERMOSTAT:
Trips when the temperature inside the stove is too high. It stops pellet loading, causing the stove to go out.
• SAFETY PRESSURE SWITCH:
This is activated if the vacuum inside the combustion chamber is insufficient for it to function correctly.
CHARACTERISTICS
120
400
- 28
-
Nominal power
12
90,0
0,015
171
2,8
12-5
25
9
315
80
40
224 - 233 / 226 - 237
Nominal power
205
0,01
8.1
230 Vac +/- 10% 50 Hz
Yes
Radio waves 2,4 GHz
T2A, 250 Vac, 5x20 Fuse
T2A, 250 Vac, 5x20 Fuse
Reduced power
3,5
kW
91,0
%
%
0,028
88
°C
0,8
kg/h
10-3
kg
31
hours
m
3
mm
mm
kg
Reduced power
106
°C
Pa
g/s
5
W
W

Publicité