OPTIONAL WIRING
WARNING DEVICES
Open-gate indicator light
• Signals that gate is open; turns off when the gate is closed.
• Contact power: 24V A.C. - 25W maximum
• Socket rating 24V-3W maximum
NOTE: If the operator detects an obstacle in the same direction twice while running,
the electronic card activates the warning device and blocks the signal from the
remote control for 5 minutes. After 5 minutes, the alarm is deactivated and the
signal for the remote controls are restored and the PROG LED goes off. To restore
normal operation prior to the 5 minutes, press the total stop key and the PROG LED
goes off.
APPLY AC POWER TO THE OPERATOR AND PROCEED TO
THE PROGRAMMING SECTION TO COMPLETE THE
OPERATOR CONFIGURATION.
PROGRAMMING
USING THE MENU
The ESC button is used to:
• exit the menu
• cancel changes
FACTORY SETTINGS (DEFAULTS)
PROGRAMMED FUNCTIONS
Total stop
CX, CY, and CZ Contacts
Speed
Automatic Close Timer (ACT)
Motor
Lingua
Italiano
{
FACTORY DEFAULTS
Enabled (NC stop)
Enabled
100%
10 seconds
Ferni
Warning
Device
USING THE MENU + FACTORY SETTINGS (DEFAULTS)
{
The <...> symbols on the display
indicate the current selection.
{
The ENTER button is to:
• press and hold for 1 second to enter the menu
• confirm and set values
The < > buttons are used to:
• move from one menu to another
• increase or decrease values
21
WARNING DEVICES