PREPARATION

TOOLS AND MATERIALS

Make sure you have all the tools and materials required for the installation. The
installation should be completed in accordance with all national and local standards
and regulations.
The following tools may be needed for your installation:
• Drill and Drill Bits
• Hack Saw
• Tape Measure

WIRING CHART

Cable list and minimum thickness
CONNECTION
120 V control panel power supply
24 V motor power supply
Flashing light
Photocell transmitters
Photocell receivers
Accessories power supply
Command and safety devices
Antenna connection
Encoder connection
NOTE: If the length of the wire differs from that specified in the table, then you must determine the proper wire gauge based on the actual power draw of the devices
connected and the local electrical codes. For connections that require several, sequential loads, the sizes provided in the table must be re-evaluated based on actual power
draw and distances. When connecting products that are not specified in this manual, refer to the instructions provided with said products.
NOTE: Use copper conductors only.

SITE PREPARATION

INSTALLATION MUST BE PERFORMED BY AN EXPERT QUALIFIED PERSONNEL AND IN FULL COMPLIANCE WITH
CURRENT REGULATIONS. Gate must be constructed and installed according to ASTM F2200 standards.
Before installation, perform the following:
1
Make sure you have a suitable omnipolar cut-off device with contacts more than 1/32" in (3 mm) apart, and independent (sectioned off) power supply.
2
Make sure the structure of the gate is sturdy, the hinges work and that there is no friction between moving and non-moving parts.
3
Make sure that there is a mechanical stop for closing.
4
Check that any connections inside the container (that provide continuity to the safety circuit) are fitted with additional insulation compared to other internal live parts.
5
Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical damage.
• Pliers
• Screwdrivers
• Shears
Cable length 3-32 ft.
3G x 14AWG
2G x 14AWG
2 x 14AWG
2 x 24AWG
4 x 14AWG
2 x 24AWG
2 x 24AWG
TOOLS AND MATERIALS + WIRING CHART + SITE PREPARATION
Cable length 32-65 ft.
Cable length 65-98 ft.
3G x 14AWG
2G x 14AWG
2 x 14AWG
2 x 24AWG
4 x 14AWG
2 x 24AWG
2 x 24AWG
max. 65 ft.
max. 98 ft.
9
3G x 10AWG
2G x 10AWG
2 x 14AWG
2 x 24AWG
4 x 14AWG
2 x 18AWG
2 x 24AWG