Factory Default Cooking Times; Programming; Turning Cooking Surfaces On Or Off; Manager Mode - Antunes ESDZ-1200 Manuel Du Propriétaire

Station à œufs à deux zones
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EGG STATION DUAL ZONE

Factory Default Cooking Times

The factory default cooking times are listed below per
button name:
Timer 1 - 3 minutes
Timer 2 - 1 minute

Turning cooking surfaces on or off

Press and hold the Program button for 5 seconds until the
unit beeps. Both displays show ON.
To turn the front cooking surface off, press the Down
arrow button.
To turn the rear cooking surface off, press the Up
arrow button.
You cannot turn both cooking surfaces off at the same
time. For example, if the rear surface is off and you try to
turn the front surface off, the rear will turn on.
NOTE: This setting is not saved. When the unit is pow-
ered off and powered back on, both cooking surfaces
are set to on.

Manager Mode

Manager mode allows access to view and change the pro-
gramming. This includes:
Adjust Timers
Adjust Rear Setpoint Temperature
Adjust Front Setpoint Temperature
Language Selection (FR-C/En)
Adjust Temperature Units (°F/°C)
Adjust Beeper (three volume levels)
View Elapsed Usage Time
View Errors
View Internal Control Board Temperature
View power line information
To enter manager mode:
1. Press and hold the Program button for approximate-
ly 5 seconds until the unit beeps. Release the but-
ton. Then, press and hold the Program button again
for approximately 10 seconds until the unit beeps.
2. The unit enters manager mode at the Adjust Timers
option. Press the desired timer to change and use
the Up and Down arrow buttons to change the time
as desired. Press the Program button to save the
change. The unit moves to the next option which is
Adjust Rear Setpoint Temperature.
®

PROGRAMMING

3. Use the Up and Down arrow buttons to change the
Rear setpoint temperature as desired. The default
is 149
the change. The unit moves to the next option which
is the Adjust Front Setpoint Temperature.
4. Use the Up and Down arrow buttons to change the
Front setpoint temperature as desired. The default
is 149
the change. The unit moves to the next option,
Language Selection.
5. To change the language between English and
French, press the Down arrow button for French
(FR-C). Press the Up arrow button for English (En).
Press the Program button to save the change. The
unit moves to the next option, Adjust Temperature
Units.
6. Use the Up and Down arrow buttons to change
the unit between Fahrenheit and Celsius. Press the
Program button to save the change. The unit moves
to the next option, Adjust Beeper.
7. Use the Up and Down arrow buttons to change the
beeper setting. There are three options with variable
volumes and sound. Press the Program button to
save the change. The unit moves to the next option,
View Elapsed Time.
8. The View Elapsed Usage Time option shows the
total time of unit operation. This option cannot be
edited. Press the Program button to move to the
next option, View Errors.
9. The View Errors option shows any errors that have
occurred. This option cannot be edited. Press the
Program button to move to the next option, View
Internal Control Board Temperature.
10. The View Internal Control Board Temperature
shows the current ambient temperature of the con-
trol board. This option cannot be edited. Press the
Program button to move to the next option, View
Power Line Information.
11. The View Power Line Information option shows
power usage information. This option cannot be
edited. Press the Program button to return to the
Adjust Timers option. From here, you can select
another timer to adjust or wait for 10 seconds for the
unit to return to operation mode.
8
300°F). Press the Program button to save
°C (
300°F). Press the Program button to save
°C (
P/N 1013028 Rev. B 10/20

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

9300643

Table des Matières