EGG STATION DUAL ZONE
Error Codes
This section describes the error codes that may appear on the
display.
NOTE: For the errors below, attempt to turn the unit
off and turn it back on again to see if the problem
is fixed. If the problem persists, refer to the Action
column.
Error
Description
1 - 9
Probable circuit board
issue.
10
Board temperature sensor
exceeds 70
158°F). The
°C (
unit shuts down.
11
Rear heat is too low, or not
reaching setpoint tempera-
ture within 30 minutes.
12
Rear Heater not operating
13
Rear thermocouple defec-
tive
14
Rear Hi Limit tripped
15
Bad front Solid State Relay
16
Front heat is too low, or not
reaching setpoint tempera-
ture within 30 minutes.
17
Front Heater not operating.
18
Front thermocouple defec-
tive
19
Front heater Hi Limit
tripped.
20
Bad rear Solid State Relay.
21
Rear platen over-tempera-
ture condition.
22
Front platen over-tempera-
ture condition.
®
TROUBLESHOOTING (continued)
Action
Contact Antunes
Technical Service
at +1-877-392-7828
(toll free) for assis-
tance.
Contact Antunes
Technical Service
at +1-877-392-7828
(toll free) for assis-
tance.
Reset the Rear Hi
Limit switch.
Contact Antunes
Technical Service
at +1-877-392-7828
(toll free) for assis-
tance.
Check power outlet
for proper voltage,
try plugging unit into
a different outlet.
Reset both Hi-Limit
switches.
Contact Antunes
Technical Service
at +1-877-392-7828
(toll free) for assis-
tance.
Reset the front heat-
er Hi Limit switch.
Contact Antunes
Technical Service
at +1-877-392-7828
(toll free) for assis-
tance.
Factory Reset
If required, the ESDZ-1200 can be reset to factory
defaults. Follow these steps to reset the unit:
1. Turn the unit off.
2. Press and hold the Up and Down arrow buttons
simultaneously. With the buttons held, press and
release the Power button. Continue holding the
Up and Down arrow buttons.
3. When the display shows Fr (Factory Reset),
release the buttons. The unit is now reset to fac-
tory default settings.
Hi Limit Control
The ESDZ-1200 has two Hi Limit resets - one for the front
cooking surface and one for the rear cooking surface. If a Hi
Limit trips, the display will show:
•
Error 14 for the rear cooking surface
•
Error 19 for the Front cooking surface.
A tripped Hi Limit shuts off power to the unit. To reset a
tripped Hi Limit switch:
1. Allow the unit to cool for 10 - 15 minutes
2. Note the error code to determine which Hi Limit has
tripped. The Hi Limit switches are located on the rear of
the unit and labeled
3. Remove both black protective cap from both Hi Limit
Switches. Press and release both buttons. Reinstall the
protective caps.
4. Turn the unit back on.
NOTE: If the Hi Limit Controls require continuous reset-
ting, contact Antunes Technical Service at 1-877-392-7854
toll free in the U.S.) or at 630-784-1000.
Figure 5. Hi Limit Control
12
F
R
for Front and
for rear.
P/N 1013028 Rev. B 10/20