Troubleshooting Continued

Error Codes

This section describes the error codes that may appear on the display.
NOTE:
For the errors below, attempt to turn the unit off and turn it back on again
to see if the problem is fixed. If the problem persists, contact Antunes
Technical Service at +1-877-392-7828 (toll free) for assistance.
Error
Error Description/
Code
E000
No Error
No Zero Cross - Internal board
E002
error
Memory Error - memory Chip
E006
error
E008
Control Board Failure
High Control Board
E009
Temperature
E011
Control Board Failure
E101
Hi Limit Tripped
Over Temp - Unit is 25°F over
E105
set point.
Under Temp - Unit is not up to
set point within 20 minutes, or
E111
temperature falls 100°F after
use.
E117
Thermocouple
E129
SSR Failure
Warmup Timeout - Unit did not
E135
reach "USE" within 20 minutes
®
Action
None Required.
Reset the unit. If the problem persists call
technical service.
Reset the unit. If the problem persists call
technical service.
Reset the unit. If the problem persists call
technical service.
Check if all bottom vents are clear and that
fan is running. If vents and fan are blocked
clean with a clean, dry, grill cloth. If the
problem persists call technical service.
Only USB memory devices should be used
in the USB connector. Reset the unit.
Reset the hi-limit (Refer to Figure 6)
Reset the unit. If the problem persists call
technical service.
Possible low power. Try an alternate outlet.
If the problem persists call technical service.
Reset the unit. If the problem persists call
technical service.
Reset the unit. If the problem persists call
technical service.
Reset the unit. If the problem persists call
technical service.
10

Hi Limit Control

If the Hi Limit trips, the display will show:
y E101 Hi-Limit
A tripped Hi Limit shuts off power to the
unit. To reset a tripped Hi Limit switch:
1.
Allow the unit to cool for 10 - 15
minutes
2.
Remove the black protective cap from
the Hi Limit Switch (Figure 6). Press
and release the button.
3.
Reinstall the protective cap.
4.
Turn the unit back on.
NOTE:
If the Hi Limit Control requires
continuous resetting, contact
Antunes Technical Service at
+1-877-392-7828 (toll free).
Figure 6. Hi Limit Control

Factory Reset

If required, the Egg Station Mini can be
reset to factory defaults. Follow these
steps to reset the unit:
1.
Turn the unit off
2.
Press and hold the Up and Down
arrow buttons simultaneously. With the
buttons held, press and release the
Power Button. Continue holding the
Up and Down arrow buttons.
3.
When the display shows Fr (Factory
Reset) release the buttons. The unit is
now reset to factory default settings.
P/N 1011587 Rev. C 11/20