To avoid possible personal injury and/or damage to the unit, inspection, test, and repair of electrical equip-
ment should be performed by qualified service personnel. The unit should be unplugged when servicing.
Problem
Unit fails to operate and
control panel lights fail to
signal on.
Unit fails to heat.
Eggs do not cook
properly.
Eggs sticking to Grill
Surface.
P/N 1013028 Rev. B 10/20

TROUBLESHOOTING

Possible Cause
No power/low power.
Inoperable electrical outlet.
Inoperable Power button.
Inoperable Power Cord.
Loose connections.
Loose connections.
Inoperable grill.
Low voltage.
Inoperable hi-limit thermostat.
Inoperable thermocouple.
Inoperable solid state relay.
Incorrect amount of water added to
trough in cover.
Grill temperature too low or high.
Loose connections.
Unit/table is not level.
Dirty Grill Surface.
Dirty Egg Rings.
Damaged Egg Ring.
If the troubleshooting steps listed do not solve your problem,
contact Antunes Technical Service at +1-877-392-7828 (toll free).
EGG STATION DUAL ZONE
WARNING
Make sure power is on and power cord is locked into
place. Check main circuit breakers.
Plug into different outlet of same amperage
rating.
Contact Antunes Technical Service.
Contact Antunes Technical Service.
Fill trough in cover with water before starting time
cycle.
Perform the steps in the section titled "Checking Grill
Surface Temperature" in this manual. The temperature
should be 149°C–163°C (300°F-325°F). If not, contact
Antunes Technical Service for assistance.
Contact Antunes Technical Service.
Level the table and unit as necessary.
Clean Grill Surface.
Do not use an abrasive scrubbing pad to clean Egg
Rings.
Replace Egg Ring.
11

Corrective Action

®

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

9300643