Note: This kit must be installed or serviced by a qualified installer, service agency or
gas supplier. These instructions are to be used in conjunction with the main installation
instructions for the above listed heater models.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
FOR INSTALLATION WITH A VALOR 530 ENGINE, READ THE
FOR 530 ENGINE CONFIGURATIONS AND VENTING,
REFER TO MAIN INSTALLATION BOOKLET SUPPLIED WITH THE
4001648-01
P
ortrait
#563SCB
Senator Cast Front
CSA approved for use only with
Valor 530
Model Heaters
INSTALLATION BOOKLET
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
FOLLOWING INSTRUCTIONS.
ENGINE.

Publicité

Table des Matières
loading

Sommaire des Matières pour Miles Industries Valor 530

  • Page 1 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR INSTALLATION WITH A VALOR 530 ENGINE, READ THE FOLLOWING INSTRUCTIONS. FOR 530 ENGINE CONFIGURATIONS AND VENTING, REFER TO MAIN INSTALLATION BOOKLET SUPPLIED WITH THE ENGINE.
  • Page 2 Casting Tolerances Due to the nature of cast iron, dimensional consistency may vary from one unit to the next and some variation in surface finish and flatness is to be expected. We have done our best to control and make allowance for this; however some variation is inevitable.
  • Page 3: Dimensions & Clearances

    INSTALLATION WITH 530 ENGINE The Valor model 50 heater with the 56SCB Senator Front comes ready for installation as a zero clearance unit into combustible type framing, without need for a separate zero clearance kit. The 530 without the standard zero clearance stand-off spacers may also be installed into existing solid-fuel burning fireplaces provided space and local codes permit.
  • Page 4 FRAMING The 56SCB Senator Front comes Bend Tabs out for desired wall supplied with a framing plate for zero finish thickness clearance applications. The framing plate is painted black and may be left exposed beyond the perimeter of the Tab Detail cast iron front or may be covered with non-combustible material if desirable.
  • Page 5 FRAMING Wall Finish 7-1/2” minimum This part of If using Top Vent, note wall must be proximity of pipe to non-combustible header (if any). See (cement board plan view on page 3. or similar) Maintain clearance to vent as listed in heater manual.
  • Page 6 INSTALLATION Mount the framing plate to the appliance. Fit the top baffle under the top panel of the Secure the framing appliance case. Secure with 2 thread forming plate and brackets screws. to the sides of the appliance case with 4 thread cutting screws supplied.
  • Page 7 appliance by removing its 11 screws. may cause a fire Fit the rear base support under the rear of the hazard and voids appliance attaching it to the appliance back warranty. panel with  x /8” thread cutting (pointed If the hooks have been shipped loose with the cast front, fix them to the front at...
  • Page 8 CLEANING It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms on the inside of the glass and causes dust, lint or other particles to cling to the glass surface. Initially, paint, while curing, may deposit a slight film on the glass.
  • Page 9 17 Finial 4001589 4001589 Hardware Kit 400109 400109 Designed and Manufactured by / for Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfireplaces.com © 2008, Miles Industries Ltd. All rights reserved.
  • Page 10 POUR INSTALLATION AVEC LE FOYER VALOR 530, SUIVEZ LES INSTRUCTIONS AUX PAGES SUIVANTES. POUR LA CONFIGURATION ET L’ÉVACUATION DU FOYER VALOR 530, CONSULTEZ LE MANUEL D’INSTALLATION FOURNI AVEC LE...
  • Page 11: Variations De La Fonte

    Variations de la fonte De par leur nature, deux articles de fonte fabriqués du même moule peuvent montrer de légères variations dans leurs dimensions et leur finition. Nous faisons tout ce qui est possible pour limiter ces variations qui ne peuvent cependant pas être éliminées.
  • Page 12: Installation Avec Le Foyer 530

    INSTALLATION AVEC LE FOYER 530 Le foyer Valor 530 combiné à la devanture Senator 563SCB est prêt à installer comme appareil à dégagement zéro dans une charpente combustible sans toutefois nécessiter de kit à dégagement zéro. Le 530 installé sans les écarteurs à...
  • Page 13 ENCASTREMENT Pliez les languettes selon l’épaisseur de la finition du mur La devanture Senator 56SCB est fournie avec une plaque d’encadrement pour applications à dégagement zéro. La plaque d’encadrement est peinte en noir Détail des languettes et peut être exposée autour de la devanture ou elle peut être couverte L’encadrement dépasse de d’un matériau non-combustible si...
  • Page 14 ENCASTREMENT Finition du mur Pour évacuation sur le dessus, 7-1/2” minimum notez la proximité Cette partie du mur entre le conduit et doit être fabriquée la poutre de tête de matériau (s’il y a lieu). incombustible Consultez le schéma (panneau de béton Vue du dessus de la ou similaire) page 12.
  • Page 15 INSTALLATION Placez le déflecteur du haut sous le panneau de Placez la plaque dessus de la boîte de foyer. Fixez-le avec 2 vis d’encadrement autoformeuses. Assurez-vous que la déviation du sur l’appareil. déflecteur est orientée vers le bas et l’avant. Fixez-la aux côtés de la boîte de foyer avec 4 vis...
  • Page 16 Fixez le support de base arrière à l’aide de 2 vis Si nécessaire, autoformeuses de 3/8”. vissez les crochets à l’arrière de la devanture. Notez bien que les crochets droit et gauche sont différents. Accrochez la devanture au foyer, plaçant les crochets dans les fentes de chaque côté...
  • Page 17: Entretien

    ENTRETIEN Il sera nécessaire de nettoyer la vitre de temps à autre. Durant l’allumage, la condensation, qui est normale, se formera et provoquera l’accumulation de poussière et de charpie à l’intérieur sur la vitre. Initialement, la peinture, lorsqu’elle durcit, peut déposer un léger film sur la vitre.
  • Page 18: Liste De Pièces

    4001589 4001589 Quincaillerie 400109 400109 Conçue et fabriqué par / pour Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, C.-B., CANADA V7H 3B1 Tél. : 604-984-3496 Téléc. : 604-984-0246 www.foyervalor.com © 2008, Miles Industries Ltd. Tous droits réservés.