Adjusting The Reduced Flame Position :
For reduced flame position the bypass screw must be loosened when converting from
LPG to NG. When converting from NG to LPG, the same screw must be tightend. Make
sure that the appliance is unpluged from the electric current and the gas feed is open.
Ignite the burners and leave them on in minimum position.
Remove the knobs because the screws are accesible only when the knobs are removed.
With the help of a small screwdriver tighten or loosen the bypass screw 90
the flame of the burner come down to the minimum (Figure 6).
When the flame has a length of at least 4mm, the gas is well distributed. Make sure that
the flame does not die out when passing from the maximum position to the minimum
position.
Changing the Gas Inlet :
The gas feeding pipe which conforms to the regulations on effect “A” placed on pipe sup-
port must be visible for all its length, it must be placed to avoid any contact with parts that will heat up.
It is recomended to always place a joint between the elbow and gas supply pipe. Spain,
Italy, Portugal, Luxemburg, Greece and Deutschland autorize the connection of the gas
hose to gas connection medium as it is shown in “B”. For these countries, the shape of
gas connection medium must conform to national rules and norms on effect.
For Denmark, Netherlands, France, Algeria, Ireland the connection is obtained by using
the pieces “E” and flexible hoses as seen in “C” or rigid pipes. This type of connection
can also be used in France, Algeria, Spain, Italy, Portugal, Greece and Luxemburg.
For the United Kingdom, The gas connection shall be carried out as shown in “D”.
In all cases, the flexible gas supply hose can neither pass behind an oven nor be
contact with combustible meterials. The minimum distance between the appliance and
adjacent surfaces must be 20mm.
After the connection had been made, it has to be tested. This test can be done by
applying a soapy liquid to the connection. No bubble should appear. If there are bubbles,
check the connection joint and remake it if necassary.
10