PART 3 : INSTALLATION AND PREPARATION FOR USE
• The appliance should be installed, regulated and adapted to function with other types of
gas by a
Failure to comply with this condition will render the guarantee invalid.
The hob should only be installed by a
He should also be a qualified electrician if the appliance requires connection to a mains
electricity supply.
The appliance must be installed in compliance with regulations in force.
Installation technicians must comply to current laws in force concerning ventilation and the
evacuation of exhaust gases.
Always unplug the appliance before carrying out any maintenance operations or repairs.
The appliance must be housed in heat-resistant units.
The appliance should be installed into a room or space with an air supply in accordance with
BS 5440-2:2000.
For rooms with a volume of less than 5 m3 - permanent ventilation of 100 cm2 free area will be
equired.
For rooms with a volume of between 5 m3 and 10 m3 a permanent ventilation of 50 cm2 free
area will be required unless the room has a door which opens directly to the outside air in which
case no permanent ventilation is required.
For rooms with a volume greater than 10 m3 - no permanent ventilation is required.
Where there are other fuel burning appliances in the same room, BS 5440-2:2000 should be
consulted to determine the correct amount of free area ventilation requirements.
The above requirements allow also for use of a gas oven and grill but if there are other gas
burning appliances in the same room, consult a qualified engineer.
Air inlet section
2
min. 100cm
Figure 1
Air inlet section
min. 100cm
5
2
Figure 2