Télécharger Imprimer la page

Proline PMC56W-F Notice D'utilisation page 36

Publicité

Les langues disponibles

Les langues disponibles

This appliance must only be connected to LPG after an LPG conversion kit has been fitted.
When operating on Butane gas a supply pressure of 28-30 mbar is required.
When using Propane gas a supply pressure of 37 mbar is required.
The installation must conform to the relevant British Standards. Warning: Only a Gas safe
registered installer, also with technical knowledge of electricity should install the oven.
He should observe the Regulations and Codes of Practice governing such installation of
gas appliances.
It is recommended that the gas connection to the cooker is installed with a flexible
connecting tube made to BS 5386.
To convert to LP gas the following steps should be performed.
Disconnect from the gas and electricity supplies.
Remove the cap and the adapter (Figure 7).
Unscrew the injectors (Figure 8)
Replace the injector with the ones corresponding to the type of gas that is going to be used,
according to the information chart at the rear of this manual.
Figure7
Figure8
9