This section describes how to install the IntelliChlor
Also, included are connection instructions for IntelliTouch
Systemssystems. Before installing, review the IntelliChlor SCG kit contents and required tools.
Note: For Power Center installation instructions, see the "IntelliChlor Power Center Installation
Guide" (P/N 520590).
Note: Salt is not provided. For details about the type of salt to use, see "What Type of Salt to Use,"
on page 11.

Kit Contents

- One IntelliChlor Salt Chlorine Generator
- Two (2) cell union with two (2) o-rings
- Installation and User's Guide (this manual)

Required Tools

- Tape measure
- Phillips and flathead screwdriver
- Pliers
- Hacksaw
- An NSF® approved all purpose PVC/CPVC/ABS cleaner primer
- An NSF® approved all purpose PVC/CPVC/ABS cement
DANGER: RISK OF ELECTRIC SHOCK, WHICH CAN RESULT IN SERIOUS INJURY OR DEATH.
Before attempting installation of service, ensure that all power to the circuit supplying power to the
system is disconnected/turned off at the circuit breaker. It is recommended, but not mandatory that the
IntelliChlor Power Center be connected to a circuit protected by a ground fault circuit-interrupter (GFCI).
Grounding (earth bonding) is required. The unit should be installed by a qualified service person and
grounded.
Install to allow access to cell buttons and power center.
Read Safety Precautions and Important Instructions (page ii and iii). Before attempting any
electrical wiring, be sure to read and follow Safety Instructions. Wiring should only be
performed by a qualified professional.
Install the IntelliChlor SCG unit a minimum of 1m (3 ft) away from the heater outlet.
Pipe couplings: Schedule 80, maximum pressure 517kPa (75 psi) at 21° C (70° F).
Note: Operate unit with minimum flow of 94 Lpm (25 gpm). For high flow applications, use a bypass
loop (see page 4) for best flow sensing.
Note: Provide at least 30-45 cm (12"-18") of straight pipe in front of the cell inlet.
®
Salt Chlorine Generator into the pool plumbing system.
®
®
, EasyTouch
When using electrical products,
basic precautions should always be
followed, including the following:
IntelliChlor Salt Chlorine Generator Installation and User's Guide
Section 5
Installation
®
and SunTouch
Control
23

Publicité

Chapitres

Table des Matières
loading