D - BATTERY CONDITION INDICATOR OPERATION
To operate, the Vac / Brush ON/OFF Switch (14) must be turned on to activate
the Battery Condition Indicator (15) to determine the charge condition of the
battery pack.
Listed below is the explanation of the Battery Condition Indicator (15) light
functions:
1
Green Indicator Light ON: Condition of battery fully charged to 75%
discharged.
2
Yellow Indicator Light ON: Condition of battery 75% to 87%
discharged.
3
Red Indicator Light ON: Condition of battery 87% to 95% dis-
charged.
3
Red Indicator Light ON and Flashing: 95% to 100% of usable
battery discharged.*
*NOTE: When the indicator starts flashing RED the operator will have 2 minutes
of run time left (for batteries in good condition). The brush motor will
automatically shut off and the vac motor will continue to run to pick up any
solution left on the floor.
Additional Note: If at any time during machine operation the battery system
voltage drops below 19 volts, the brush and vac motors will immediately shut
off. The red light will also flash for 5 seconds to indicate a low voltage fault
condition. Check condition of batteries and recharge them.

TECHNICAL SPECIFICATIONS

Model
Model No.
Current
Voltage, batteries
Battery capacity
Protection grade
Sound pressure level as per ISO3744 (at operator position)
Total weight (with full sol. tank and batteries)
Net weight (with empty tanks and no batteries)
Vibrations at the Hand Controls
VAC / BRUSH SWITCH INDICATOR LIGHT FUNCTIONS
The green Vac / Brush Indicator Light shows 3 different machine operation
conditions as follows:
Indicator Light OFF: Motors shut off.
Indicator Light ON: Motors run.
Indicator Light flashing at (4) flashes per second: Motor overload
condition (same as tripped circuit breaker).**
**: If an overload occurs, determine and correct the cause of the overload. The
machine has an internal electronic circuit breaker built into the control board.
To reset the electronic circuit breaker, turn the Vac / Brush ON/OFF Switch (14)
off and then back on.
TROUBLESHOOTING
POOR WATER PICKUP
1
Recovery tank full, float shut-off closed
2
Blocked vacuum system (squeegee hose and float cage)
3
Disconnected or damaged vacuum hoses
4
Blades worn or damaged
5
Recovery tank cover not seated properly
6
Recovery tank cover gasket damaged

SQUEEGEE STREAKS

1
Debris under the squeegee blade
2
Worn, nicked or torn squeegee blade
3
Debris build up on the squeegee blade

SWIRL MARKS

1
Running the machine with a dry brush or pad (no cleaning solution)
2
Incorrect brush or pad for the application
3
Debris caught in brush (or pad)
A
V
Ah
dB (A)/20µPa
lbs / kg
lbs / kg
m/s
2
FORM NO. 56041365 / Micromatic
Micromatic™ 17B
56302100
40
24V/2 x 12V
105
IP23
71
355 / 160
144 / 65
<2.5m/s