Mounting in existing immersion
sleeves
In Germany the C5 can be put into
use in connection with existing im-
mersion sleeves in accordance with
the article "Putting into use of MID
homologated temperature sensors"
released in the PTB notifications
119 (2009), vol.9. Based on current
information, the regulation has a pe-
riod of validity until 30.10.2026. For
the identification and marking of the
usable existing immersion sleeves
in connection with the C5 meter, an
identification and marking set can be
delivered from our company (order
number 137382).

Putting into use

Open valves carefully and chek
installation for leakage.
If the sleep mode of the counter is
enabled (Display: SLEEP 1), then
it must be deactivated by longer
pressing the button (>5s).
While the system is operating,
check whether the volume display
advances and the temperatures
displayed correspond with the ac-
tual temperatures (see the display
overview).
Wait for the temperature display
to be updated.
Secure meter with the enclosed
sealing material against unautho-
rised removal.
Fill in the putting into use report
in accordance with PTB-Directive
TR K9.
26
Français
Important notes:
Only for special version with pro-
grammable place of installation
of the flow sensor.
The meter is in the delivery status in
sleep mode (SLEEP 1). If the meter
is being awakened from the sleep
mode, the place of installation on
the following two display screens
can be selected.
The choice of the place of ins-
tallation can be carried out only
once. A subsequent change is
not possible.
With a short button press you can
choose between the following two
displays.
Installation return:
Installation flow:
!! IMPORTANT !!
If this indicator appears on the
display, the counter is still in
sleep mode. Only when the instal-
lation position has been selected,
the device is fully awakened.