Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

POWER-SPIN
Clamp
Screw
Figure 9 – Installing Cable End Into Holder
5. Replace drum back and retighten the 4
screws.
6. Feed cable into drum.

Troubleshooting

PROBLEM
Cable kinking or break-
ing.
Cable won't feed.
10
®
Drain Cleaner
POSSIBLE REASONS
Cable is being forced.
Cable used in incorrect pipe diameter.
Motor switched to reverse.
Cable exposed to acid.
Cable worn out or damaged.
Cable not properly supported.
Cable bearings are dirty or greasy.
AUTOFEED not fully engaged.
SOLUTION
Do Not Force Cable! Let the auger do
the work.
Do not use in lines over 1
Use reverse only if cable gets caught in
pipe or to retract cable.
Clean cables routinely.
If cable is worn or damaged, replace it.
Support cable properly, see instructions.
Clean cable and bearings with hot,
soapy water.
Be aware and squeeze trigger harder.
1
/ " (40 mm).
2

Publicité

Table des Matières
loading

Table des Matières