(7) ELECTRICAL CONNECTION
IT IS MANDATORY TO GROUND THE EQUIPMENT: To avoid possible discharges on individuals or damages to the
equipment, the machine should be grounded pursuant local and/or national regulations as the case may be.
THE MANUFACTURER SHALL BE HELD HARMLESS IN CASE OF DAMAGES ARISING DUE TO THE LACK OF THE GROUND
INSTALLATION.
In case the supply cable is damaged, it should be replaced by a cable of special assembly to be furnished by the
manufacturer or after-sales service. Such replacement should be performed by qualified technical service only.
The machine should be places in such a way as to allow a minimum space between the back and the wall to allow an
easy access and without risks to the cable plug.
Safeguard the socket. It is convenient to install adequate switches and fuses.
Voltage is indicated in the nameplate and on the technical specifications of this manual. Variation on voltage above
the 10% stated on the nameplate could result on damages or prevent the machine start-up.
VOLTAGE
MODELS
FREQUENCY
PHASE
SPIKA NG 125-1
115V / 60Hz / 1Ph
SPIKA NG 175-1
115V / 60Hz / 1Ph
SPIKA NG 215-1
115V / 60Hz / 1Ph
SPIKA NG 285-1
115V / 60Hz / 1Ph
SPIKA NG 440-1
115V / 60Hz / 1Ph
SPIKA MS 440-2
208-230V / 60Hz / 1Ph
SPIKA MS 880-2
208-230V / 60Hz / 1Ph
(8) INSTALLATION OF MODULAR EQUIPMENTS ON TOP OF BINS
Modular ice makers should be installed on top of bins, following the instructions contained in this manual.
The resistance and stability of the container-machine/s assembly should be verified, as well as the fastening elements.
Follow bin manufacturer instructions.
(9) REMOTE CONDENSER MODELS
Machines with remote condenser consist of an ice machine, remote condenser and interconnecting refrigerant pipes.
Due to the remote condenser, these machines dissipate heat at a convenient location, away from the ice maker. The
machines reduce the air conditioning loads.
SPIKA MS 500 – R1H/F 115/60 REMOTE + REMOTE CONDENSER RC5
SPIKA MS 1000 – R2H/F 208-230/60 REMOTE + REMOTE CONDENSER RC10
9.1 INSTALLATION AND CONDENSER LOCATION
To install the machine correctly, follow the instructions:
1) Ambient operating temperature -20°F (-28.9°C) to 120 ºF (48.9°C)
TOTAL
MAXIMUM FUSE /
AMPS
CIRCUIT BREAKER
(A)
(A)
6
15
5,5
15
6
15
8,7
15
14,5
14
9
15
10
15
5
USER MANUAL SPIKA
POWER
NEMA
CORD
3AWG16
5-15P
3AWG16
5-15P
3AWG16
5-15P
3AWG16
5-15P
3AWG16
5-20P
3AWG16
6-15P
3AWG16
6-15P