3.2.1 Mechanism section
Item
Head
Test tape
azimuth
: VT703L (8kHz)
Output terminal
: Speaker out
Tape speed
Test tap
: VT712 (3kHz)
Output terminal
: Speaker out or
Headphone out
Item
Test tape
Tape speed
: VT712 (3kHz)
diviation at
Output terminal
FWD/REV
: Speaker out or
Headphone out
Wow & Flutter
Test tape
: VT712 (3kHz)
Output terminal
: Speaker out or
1-20 (No.22044)
Condition
1.Playback the test tape VT703L (8kHz).
2.Adjust to maximum output level by azimuth
adjustment screw for forward side and reverse
side.
3.This adjustment is adjust by adjustment screw
of forward side and adjustment screw of reverse
side.
Playback the test tape VT712 (3kHz) at end of
forward side,adjust to 2,940~3,90Hz indication
of frequency counter by VR37.
Condition
Playback the test tape VT712 (3kHz) at end
of forward and reverse, tape speed deviation
should be less than 6.0Hz.
Playback the test tape VT712 (3kHz) at
start of forward and reverse,Wow & Flutter
are should be less than 0.25%(WRMS).
Headphone out
Measurement method
Measurement method
Adjustment
Ref.value
position
Only adjust
Maximum
at changed
output
head
2,940 ~
VR37
3,090Hz
Adjustment
Ref.value
position
Leass than
VR31
6.0Hz
Less than
0.25%
(WRMS)