JVC UX-H33 Manuel D'instructions page 22

Masquer les pouces Voir aussi pour UX-H33:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

UX-H33
3.3 Flow of functional operation until TOC read (CD)
Power ON
Tracking error waveform at TOC reading
Approx.3sec
pin 20 of
IC601(TE)
Approx
1.8V
VREF
Tracking
servo
off statas
Disc statas
to rotate
Automatic measurement
of TE amplitude and
automatic tuning of
TE balance
1-22 (No.22044)
Power Key
Automatic tuning of
Automatic measurement of
Focus A-curve amplitude
Automatic measurement of
Tracking error amplitude
Tracking
Disc to be
servo
braked to stop
on statas
Automatic tuning of
TOC reading
finishes
Tracking error balance
500mv/div
2ms/div
Fig.1
Slider turns REST
SW ON.
Automatic tuning
of TE offset
Laser ON
Detection of disc
Foucus offset
Disc is rotated
Focus servo ON
(Tracking servo ON)
Automatic tuning of
Focus error balance
Automatic tuning of
Focus error gain
Automatic tuning of
Tracking error gain
TOC reading
Play a disc
Check Point
Check that the voltage at the pin4
of CN601 is 0V (a moment)?
Check that the voltage at the
pin2 of IC601 is 0V?
Confirm that the Focus error
S-cuve siganl at the pin23 of
IC601 is approx.2Vp-p
Confirm that the siganl from
pin22 IC603 is 0V as a
accelerated pulse during
approx.400ms.
Confirm the waveform of
the Tracking error signal
at the pin20 of IC601
(See fig-1)
Confirm the eys-pattern
at the lead of TP1

Publicité

Table des Matières
loading

Table des Matières