4
Setting Up
4.1
Unpacking
en
⇒ Remove the device and all the accessories from the delivery package�
⇒ Check the delivery for completeness (refer to the Scope of Delivery section)�
4.2
Setup
The extraction unit is a free standing appliance which must not be operated in a lying position�
Position the extraction device so that:
• The exhaust vent (7, Fig� 1) is not blocked�
• The front of the device is easily accessible for removal of dust drawer�
If the device is to be installed in a cabinet, an opening for the exhaust air with the following dimensions
must be provided, in addition to the openings for the suction hoses:
• Circular opening:
• Rectangular opening:
It is advisable to use external ventilation (see accessories) (see chapter 4�6)�
4.3
Electrical Connection
Before connecting the device, ensure that the voltage in-
formation on the identification plate corresponds with your
local power supply.
Arrange the conducting parts (plug sockets, plugs and cou-
plings) and install the extension cord so that the protection
class is retained.
⇒ Switch the device OFF at the On / Off switch (9)�
⇒ Connect the power cable (5, Fig� 1) to the power supply (10)�
⇒ Insert the power plug into the building installed wall socket�
4.4
Connection to the Extraction Point
⇒ Insert the suction tube (6, Fig� 1) into the suction port (8)�
⇒ Connect the suction tube to the relevant suction point�
⇒ If necessary, shorten the suction tube�
Caution, risk of injury!
When shortening the suction tube, please ensure that the
integrated wire is cut as straight as possible.
If the diameter size does not correspond, please use an
adapter (see accessories) to prevent a loss in suction per-
formance.
Long suction hoses, tight bends and kinks will consider-
ably reduce the extraction force at the extraction point.
Avoid steep pitches or hanging points along the hose path.
4.5
Electrical Connection
⇒ Connect the electronic device to the power socket (12) at the
back�
When connecting an electronic device to the extraction
unit, please ensure that the maximum permissible capac-
ity for connected devices is not exceeded. (See chapter
8. Technical data).
Min� 120 mm diameters�