Télécharger Imprimer la page

Aqua Medic EVO 500 Mode D'emploi page 12

Écumeur interne à moteur pour aquarium jusqu'à 250 litres
Masquer les pouces Voir aussi pour EVO 500:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Wet foam
First of all, lower the water level in the skimmer by turning the water level controller (Fig. 1, No.
4). With freshly prepared salt water or after using water conditioners or at extremely high loading,
excessive wet foam may be produced. This wet foam is forced into the cup, requiring more
frequent emptying than normal. After approx. one day, the aquarium load should be normal and
the skimmer will produce correct foam.
In new set-up aquaria, there is usually no reasonable skimming. The skimmer produces
large quantities of wet foam. This is normal and can be adjusted with the controller until
the foam cup is no longer full.
Dry foam / not enough bubbles
Not enough or too dry foam could be an indication that the needle wheel or air injection nozzle is
dirty. A thorough cleaning is recommended. Remove the pressure nozzle from the pump. If it's not
a problem of cleaning, increase water level inside the skimmer by the water level controller.
7. Maintenance
The collection cup should be cleaned regularly (daily or weekly, depending on organic load). The
reaction pipe of the skimmer needs to be cleaned only occasionally. The venturi pump should also
be removed and cleaned regularly so there is no negative impact on the air output. The pump has
to be removed and the complete pump housing and needle wheel flushed with clean water. The
same procedure should be undertaken with the air injection nozzle.
8. Warranty
Should any defect in material or workmanship be found within 12 months of the date of purchase
AB Aqua Medic GmbH undertakes to repair or, at our option, replace the defective part free of
charge – always provided the product has been installed correctly, is used for the purpose that was
intended by us, is used in accordance with the operating instructions and is returned to us carriage
paid. The warranty term is not applicable on all consumable products.
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer's
name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty
may not apply if any model or production number has been altered, deleted or removed,
unauthorised persons or organisations have executed repairs, modifications or alterations, or
damage is caused by accident, misuse or neglect. We regret we are unable to accept any liability
for any consequential loss. Please note that the product is not defective under the terms of this
warranty where the product, or any of its component parts, was not originally designed and / or
manufactured for the market in which it is used. These statements do not affect your statutory
rights as a customer.
If you have any questions your dealer cannot answer please contact us. We reserve the right to
modify and adjust the specification of our products without prior notification.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
- Technical changes reserved – 09/2015