Troubleshooting; Error Message List - Boss LOOP STATION RC-30 DUAL TRACK LOOPER Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43

Troubleshooting

Problem
Recording does not end
immediately when you
press the right pedal
Recording started
immediately even
though Auto recording
mode is selected
Cannot change the
playback tempo

Error Message List

Display Meaning
The battery has run low.
bt
Memory is full.
FL
This WAV file is unplayable.
UF
Further overdubbing is not possible.
EF
Internal memory must be formatted.
Er
The RC-30 has malfunctioned.
dN
18
Action
If rhythm is on, or if you recorded a phrase that is shorter than the minimum recording time
(approximately 1.5 seconds), the length of the phrase is adjusted automatically; this may mean
that recording does not end immediately when you press the right pedal.
If due to distortion or other causes there is a significant amount of noise, that noise may be
enough to trigger the beginning of recording. Reduce the noise, for example by lowering the
distortion level.
You cannot change the playback tempo in the following situations.
• If the phrase has not been saved.
• While phrases are being switched (PLAY indicator blinking rapidly).
• When you attempt to set the tempo for a phrase that is looped over an interval shorter
than the minimum recording time (approximately 1.5 seconds).
Action
Replace the battery.
Delete unneeded phrases.
Check the format of the WAV file.
Re-save the phrase.
Format the RC-30's internal memory.
Contact your dealer.