4.4.2.
Battery Charger
Follow the steps listed in Table 4-4 to help determine what might be wrong if the charger doesn't
appear to be operating properly.
LED remains OFF when connected to
AC mains power
LED remains ON after 6.5 hours of
charging
LED blinks slowly all the time
LED blinks quickly
Orange LED does not come on (Cell-
Con only)
4.5.

Replacement Parts

There are no replacement parts available for the 64060625 battery pack. If the unit fails, the entire
battery pack must be replaced. Only the 3m (10 ft.) blue battery cable assembly with connector is
available as a replacement part. Information on the cable assembly is shown below in Figure 4-5
and Table 4-5.
4-6
METTLER TOLEDO NiMH Battery Pack Installation/Technical Manual
Table 4-4: Battery Charger Diagnostics
Condition
Measure the AC mains power. If the AC power is normal, the battery
charger may be defective.
Battery may not be accepting a charge and is defective. Replace the
battery and check charger operation.
Check battery voltage. If battery voltage is 12-14 VDC, battery may
be fully charged. If voltage is lower than 11 VDC, charger may be
defective.
Maximum battery temperature exceeded. Battery or charger might be
defective. Test charger with another battery to determine which item
is defective.
When charging consecutive batteries, wait 15 seconds after
disconnecting from one battery before connecting to the next.
Figure 4-5: Battery Cable