POSSIBLE TROUBLESHOOTING
7) Signalling:
smoke °C/high.
Problem:
turns off due to exceeding maximum smoke temperature.
Actions:
• Check the pellet type
• Check for anomalies with the smoke extraction motor
• Check to see if there are any obstructions in the smoke channel
• Check correct installation
• Check gear motor "drift"
• Check to make sure there is an air intake in the room
8) Signalling:
ALARM - HIGH CURRENT: Activated when anomalous, excessive current absorption is detected on the
gear motor..
Actions:
Check functioning (CAT): gear motor - Electrical connections and electronic board.
9) Signalling:
ALARM - LOW CURRENT: Activated when anomalous, insuf cient current absorption is detected on the
gear motor.
Actions:
Check functioning (CAT): gear motor - pressure switch - tank thermostat - electrical connections and electro-
nic board
10) Signalling:
"Battery check"
Problem:
The insert does not stop but the error appears on the display.
Actions:
• The buffer battery of the control board needs changing (DEALER).
Remember that this component is subject to regular wear and so it is not covered by the guarantee.
11) Problem:
Remote control not working
Actions:
• closer to the receiver of the insert
• check the battery and if necessary, replace it.
12) Problem:
Outlet air not hot
Actions:
• clean heat exchanger from inside the rebox.
13) Problem:
During ignition, the differential switch trips (DEALER):
Actions:
• check moisture content of ignition resistance
14) Problem:
Does not ignite:
Actions:
• clean combustion chamber.
NOTA
Warnings are shown until you intervene and press the 0/1 key on the control panel.
Do not ignite the stove until the problem has been checked and resolved.
N.B.:
The combustion chambers and smoke ducts connected to the solid fuel appliances must be cleaned once a year (check
if your country has specifi c legislation covering this).
Failure to regularly check and clean increases the likelihood of a fi re in the chimney pot.
In the case of a fi re in the stove, in the fl ue or in the chimney, proceed as follows:
- Disconnect the power supply
- Use a carbon dioxide (CO
2
- Call the fi re brigade
DO NOT ATTEMPT TO PUT THE FIRE OUT WITH WATER!