If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
WARNING
!
To avoid possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
5.1
Connect the green grounding lead from the hanger ball
and the green grounding lead from the hanger bracket to
the grounding conductor of supply (this may be a bare
wire or wire with green colored insulation). Securely
connect wires with wire connectors (supplied) (Figure 16).
WARNING
!
This product is designed to use only those parts supplied
with this product and/or any accessories designated
specifically for use with this product by Emerson Electric
Co. Substitution of parts or accessories not designated
for use with this product by Emerson Electric Co. could
result in personal injury or property damage.
5.2
Securely connect the fan motor white wire to the supply
white (neutral) wire using wire connector (supplied)
(Figure 17).

5. How to Wire Your Ceiling Fan

GROUND
CONDUCTOR SUPPLY
LISTED WIRE
CONNECTOR
GREEN WIRE
(GROUND) FROM
HANGER BALL
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
Figure 16
Figure 17
12
SUPPLY WHITE
(NEUTRAL)
LISTED WIRE
CONNECTOR
FAN MOTOR
WHITE WIRE
U.L. Model No.: CF500