DESCRIPTION
The Lo-Carbon Svelte 125mm fan is an axial extraction fan suitable for domestic
bathrooms, W.C's, kitchens and utility rooms. They are available as wall or panel
mounted models with shutter timer and humidity combinations.
Long life ball bearing DC motor with anti-vibration mounts provides low noise
transmission into plasterboard/panels.
High and low speed options available on all models to suite the installation.
The fan can be wall or panel/ceiling mounted.
ACCESSORIES (not supplied)
WALL KIT
A 125mm wall kit is available for installing into most
walls using the liners supplied.
A. INSTALLATION
IMPORTANT: The fan should only be used in conjunction with fixed wiring.
PANEL/CEILING MOUNTING
1.
For panel/ceiling mounting the fan should be installed into a closed duct system
of at least 1.2m long (max 3m) or protected by an exterior air grille that must
comply with the standard requirements of your country to prevent access to the
fans impeller.
2.
Cut a 130mm hole for 125mm fans.
3.
Loosen the screw at the bottom of the grille and remove the front grille. Mark
the screw centres through the holes in the fan back plate. Drill, plug and screw
into position.
4.
Attach ducting as required for the installation.
5.
Wire the fan as described in Section B-Wiring. Adjust any settings as required
(see Section C-Setup).
6.
Replace the grille and tighten the retaining screw.
7.
After installation, ensure impeller rotates freely and the shutters can open.
WALL MOUNTING
1.
For wall mounting cut a 140mm diameter hole for 125mm fans, through the wall
and insert the wall sleeve. Slope the sleeve slightly downwards away from the
fan. Cut to length and cement both ends into position flush with the wall faces.
2.
Loosen the screw in the bottom of the grille and remove the front grille. Mark the
screw centres through the holes in the fan back plate. Drill, plug and screw into
position. Fix exterior grille into position with the louvres positioned downwards.
(Note:-The grille must comply with the standard requirements of your
country to prevent access to the fans impeller. The wall kit used in this
installation should provide a minimum ducting length of 100mm from the fans
back plate to the inside of the external grille).
3.
Wire the fan as described in Section B-Wiring. Adjust any settings as required
(see Section C-Setup).
4.
Replace the grille and tighten the retaining screw.
5.
After installation, ensure impeller rotates freely and the shutters can open.
3
Stock Reference
Wall Kit
White
125
8000000026
EN