3.5 Address assignment of the valve solenoid coils
Addresses are assigned to the valve solenoid coils in
ascending order without gaps, from left to right.
Depending on the manifold block, a valve location
occupies one address (CPA..−EV1) or two addresses
(CPA..−EV2). If a manifold block occupies 2 addresses, the
following applies:
pilot solenoid 14 lower−value address,
pilot solenoid 12 higher−value address.
Examples: Fitting equipment in the valve locations
2 double−solenoid
valves (EV2)
1
1 3
0 2
1
Output adresses (O0 ... O3)
24
1 double−solenoid valve (EV2)
2 single−solenoid valves (EV1)
1
1
0
2 3
Festo CPA..−ASI−4E4A−Z 0303NH English