GATE FITTING
The gate fitting must be installed so that it is horizontal relative to the
post bracket. The distance between the gate bracket and post
bracket is referred to as the "arm span". When the gate is closed, the
drive mechanism is 99% extended. When the gate is opened, the
drive mechanism is 1% extended. Fully retracting or extending the
plunger/spindle in operation (with gate) damages the drive
mechanism and voids the warranty. It is absolutely imperative to
comply with the required arm span under all circumstances!
For steel gates, fixings should be welded on or through bolted. When
through bolting the gate, use large washers or a plate on the other
side. The drive mechanism exerts an extremely high force on this joint.
Fixings must be through bolted for wooden gates. Wood deflects
under load and the bolt will become loose. Due to movement caused
by repeated loading, the wood deflects more and more until the gate
no longer closes correctly and has to be repaired.
Fit a reinforcing plate from the outside and one on the inside so that
the wood cannot deflect and the joint cannot become loose.
Thin wooden gates without a metal frame must also be reinforced in
order to withstand continuous stresses (e.g. type F).
6
RELEASE
The drive mechanism can be released. The gate can then be opened
and operated manually (power failure). With a new drive mechanism,
the release action may sometimes feel stiff/jerky. This is normal and
has no effect on function.
Release: Insert the key in the cylinder lock and turn it 180 degrees.
Then turn the release lever 180 degrees – done!
Engage: Turn the lever glockwise. As soon as the gate moves or the
drive runs, the gear locks again. Use the lock to protect the lever
against unauthorized release.
INSTALLING THE DRIVE ARMS
Release the drive. Push the released drive onto the fittings and
secure it by using the supplied bolts, nuts and rings.
„If the centre or inner hole, on the hinge plate, is used to fix the post
fixing bracket you MUST cut away the remaining section of the hinge
plate before activating the arms. Failure to do so will result in
breaking the fixing bracket".
Do not use a hammer when you mount the operator on the bracket.
7
WIRING
230 VOLT: The 4-pole connecting cable is approx. 80 cm long and is
laid in a curve to the controller or a watertight distribution box located
above ground. An approved cable is permanently installed from the
distribution box onwards. The capacitor can be connected inside the
distribution box or in the controller.
Connection: Connect the capacitor across terminals OP and CL.
OP and COM produce rotation direction A. CL and COM produce
reversed direction of rotation. Always remember to earth the
installation (figure 7B).
24 VOLT: The connecting cable has 6 wires, is approx. 80 cm long
and is run in a curve to the control unit or to a watertight distribution
box located above ground. A permanent connection is formed from
the distributor box via an appropriate cable.
Connection: See control unit instructions.
Cable colours: Brown/Green/White/Yellow=sensors
Blue/Red: 24 volt motor.
ACCESSORY TIP: Extension cable LA400-JB40
Contains:
(1) 12m cable with terminals
(1) Distribution box IP65
(2) Strain relief PG 13,5
(1) Mounting material
INIATIAL OPERATION
Check functionality in a disengaged state with the hand on the gate.
Initial electrical operation is only possible with a suitable control unit
that can be purchased as an accessory. Ensure at all times that
mechanical and electrical safety instructions applying to the given
installation are complied with.
Should the force of the moving wing at its closing edge be higher
than 400N , then additional safety facilities (light barrier, contact
strip) must be used. Any safety facilities must comply with the
requirements set out in EN60335-2-103.
7
MAINTENANCE WORK
The drive mechanism is maintenance free. Check that the gate fittings
and the drive mechanism are securely fixed at regular intervals
(monthly). Release the drive and check that the gate functions properly.
Unless the gate runs smoothly it will not operate correctly with the drive
mechanism. The drive cannot eliminate the problems caused by a gate
that does not work satisfactorily.
24Volt drives: also see owners manual of Electronic Control.

TECHNICAL DATA

230Volt
Mains supply (Motor)
Motorspannung
Current consumption
Power consumption
Capacitor
Max. gate width
Max. gate weight
Protection Class
Connecting cable
Rated Thrust
Travel Speed
Rated operating time
Temperature
24Volt
Mains supply (Motor)
Motorspannung
Current consumption
Power consumption
Max. gate width
Max. gate weight
Protection Class
Force (nominal)
Travel Speed
Opening time 90° sec.
Temperature
D e c l a r a t i o n o f C o n f o r m i t y
Automatic Gate Opener Models LYN300 Series, LYN400 Series, SCS300 Series
are in conformity to the applicable
sections of StandardsEN300220-3 • EN55014 • EN61000-3 • EN60555, EN60335-1 • ETS
300 683 • EN60335-1: 2002 • EN60335-2-103: 2003 • EN55014-1: 2000 + A1 + A2 •
EN55014-2: 2001 • EN61000-3-2: 2000 • EN61000-3-3: 1995 + A1 • EN 301 489-3,
V1.3.1 • EN 300 220-3 V1.1.1 • EN 13241-1
per the provisions & all amendments
of the EU Directives .............................................2006/95/EC, 2004/108/EC, 1999/5/EG
D e c l a r a t i o n o f I n c o r p o r a t i o n
Automatic Gate Opener Models , when installed and maintained according to all the
Manufacturer's instructions in combination with a Gate, which has also been installed and
maintained according to all the Manufacturer's instructions, meets the provisions of EU
Directive 89/392/EEC and all amendments.
I, the undersigned, hereby declare that the equipment
specified above and any accessory listed in the manual
B.P.Kelkhoff
Manager, Regulatory Affairs
Chamberlain GmbH
D-66793 Saarwellingen
January, 2008
220 – 240Volt ˜ / 50Hz
220-240 Volt
1.2A
280W
6.3μF
2.5m LYN300
4.0m LYN400
3.0m SCS300
250kg
I - IP 44
H07RN-F / 80cm
250N
20mm/s LYN300, SCS300
12mm/s LYN400
4 Minuten
-20
o
C up to + 55
o
C
220 – 240Volt ˜ / 50Hz
24Volt
2A
48W
2.5m LYN300
4.0m LYN400
3.0m SCS300
250kg
I - IP 44
250N
variabel
approx. 12 LYN300
approx. 14 LYN400
approx. 10 SCS300
-20
o
C up to + 55
o
C
conforms to the above Directives and Standard
s.