Do not operate the vacuum cleaner with
a full container! Do not vacuum large
amounts of liquid at a time (e.g. with the
hose immersed into water).
If the water exceeds the maximum level during
vacuuming, the fl oat will automatically block the suction.
The maximum capacity of the container is about 5 l.
In such a case proceed in the manner described above
in the part concerning the blocking of suction caused by
a dirty foam fi lter (pulsating motor speed).
END OF OPERATION CLEANING AND
MAINTENANCE
● Switch off the vacuum cleaner by pressing the on/off
button (8) and unplug the appliance.
● Wind the cord by pressing the cord rewind button (9).
While doing this hold the cord to make sure it is not
tangled and the plug does not hit the vacuum cleaner
housing.
● Turn the end of the hose until the tops of the marks
on the end of the hose end and on the vacuum
cleaner housing are in the same position and pull the
hose out of the opening.
● Remove the stub pipe of the hose by pressing the
red button on the valve and pull the stub pipe.
● Disconnect the telescopic tube from the hose and
the nozzle or brush.
● Pour the dirty water out of the container.
● It is recommended to wash the container, fi lters
(disassembly below) and partition thoroughly after
each use – changing water several times.
● After using the wet cleaning function thoroughly
wash all attachments used in this process (hose, tubes,
accessories).
If you do not clean the above-mentioned
parts or clean them insuffi ciently it may
lead to the loss of the fi ltration
capabilities of the inserts and foam and cause
the formation of bacteria and mites. Dry all the
cleaned parts thoroughly before reassembly.
FILTER DISASSEMBLY
FOAM FILTER I
1
Open the lid of the fi lter unit by pulling the handle
upwards.
2
Take out the fi lter, wash it under running water, dry
and reinsert.
● Close the fi lter unit lid by pressing it until you hear
a characteristic click.
FOAM FILTER II
It is recommended to wear rubber protective gloves
while dismantling the fi lter.
1
Grab the foam fi lter with your fi ngers and remove it
from the fi lter unit body.
2
Wash under running water, dry and reinsert.
Do not hand wash the fi lter foam, do not
wring it, do not wash it in washing
machines. Avoid crumpling, stretching
and deforming. After cleaning dry the foam in
room temperature. Never dry the foam on
heaters, stoves, etc.
INLET FILTER
1
Remove the SAFBAG (21) dust bag module from
the container.
2
Take out the SAFBAG dust bag from the module
(see chapter TRADITIONAL CLEANING WITH SAFBAG
DUST BAG -disassembly/assembly of the SAFBAG
dust bag).
3
Release the fastening hook which fi xes the lid of
the SAFBAG dust bag module with the basket and pull
the basket aside.
4
Take out the fi lter, wash it under running water, dry
and reinsert.
● Close the basket of the SAFBAG dust bag module
by pressing it until you hear a characteristic click.
● Insert SAFBAG dust bag (see chapter
TRADITIONAL CLEANING WITH SAFBAG DUST BAG
–disassembly/assembly of the SAFBAG dust bag).
EPA OUTLET FILTER AND COOLING AIR FILTER
The EPA outlet fi lter should be replaced after about
30 hours of operation (6 months) or earlier in case of
heavy dirt.
1
Slide the slider of the fi lter cover interlock downwards
and open the fi lter cover.
2
Remove and replace the EPA fi lter with a new one
when the fi lter becomes dirty.
3
Remove and replace the motor fi lter with a new
one when the fi lter becomes dirty.
G
4
It is possible to rinse the EPA fi lter and the cooling
air fi lter under running water. Remember to dry the
above mentioned fi lters before reassembly.
● Close the fi lter cover and slide the interlock slider
upwards.
H
I
J