DIODE TEST
1. Insert RED test lead into VΩ jack
COM jack
4
Continuity/Resistance/Diode-Test
Black lead Red lead
NOTE: The meter defaults to Continuity testing in this mode. Press
the SEL/DC ZERO" button
Diode icon
2. Touch test leads to diode. A reading of 200-800mV on display
indicates forward bias, "OL" indicates reverse bias. An open
device will show "OL" in both polarities. A shorted device will
show approximately 0mV.
FREQUENCY / DUTY-CYCLE
1. Insert RED test lead into VΩ jack
COM jack
Frequency/Duty-Cycle
Black lead Red lead
NOTE: : The meter defaults to Frequency testing. To test Duty-Cycle,
press the "SEL/DC ZERO" button
icon (either Hz or %) appears on the display.
1. Measure by connecting test leads across the circuit.