SELF-CLEANING
The Self-Cleaning function removes the scales and minerals built up in the Steam
Chamber. The iron will remain in optimal condition if this function is performed at least
once a month (or more often), depending on the hardness of water used.
1. Unplug the Power Cord from electrical outlet.
2. Move the Steam Selector to
3. Fill the Water Tank as described in this manual.
4. Plug in the Power Cord to electrical outlet.
5. Switch on the iron and select the "MAX" temperature setting.
6. Temperature Indicator Light will blink when iron is heating up.
7. Temperature Indicator Light will stop blinking and stay on when MAX temperature
is reached.
8. Disconnect the Power Cord from electrical outlet.
9. Hold the iron horizontally over a sink.
10. Press and hold the Self-Clean Button.
11. Steam and boiling hot water containing scale and
mineral deposits will release from the soleplate holes,
cleaning out the steam chamber.
12. Gently move the iron back and forth until Water Tank
is empty.
13. When self-cleaning is completed, release the Self-
Clean Button.
14. Plug in the Power Cord to electrical outlet and set the
iron to "MAX" temperature setting.
15. When the Temperature Indicator Light stays on, move
the iron gently over a piece of used cloth to remove
any water stains that may have formed on the soleplate.
16. Disconnect the Power Cord from the electrical outlet and position steam iron back
on its heel rest. Wait for iron to completely cool down before storing.
WARNING: Do not put vinegar or other descaling agents in the Water Tank.
WARNING: Keep skin/body away from the hot water and steam.
Using Your SteamLogic Plus
Steam Iron
position.
ENGLISH – 9