SPECIAFICATION & COMMERCIAL DUTY 3
DIMENSION
Model
BMF40-90NAT&LP
BMF50-120NAT&LP
BMF70-150NAT&LP
GAS SUPPLY AND BURNER INFORMATION
Supply pressure should be at minimum of 4" W.C. for natural gas or 10" W.C. for propane. The fryer comes with ¾" NPT male
connector on a ½" pipe, allowing you to connect with either ¾" or ½" NPT female connector.
Model
Burners
BMF40-90
Main
BMF50-120
Main
BMF70-150
Main
*
Minimum supply pressure is 4" W.C. for natural gas and 10" W.C. for propane.
**
Orifice sizes are for units installed at altitudes between 0 and 2000 feet above sea level.
Commercial Duty 3
5004906
Width (in)
Depth (in)
A
B
C
15.5 14.0
30.3
14.0
15.5 14.0
30.3
14.0
21.0 18.0
30.3
14.0
Gas
Manifold
Type
Pressure
Natural
4" W.C.
Propane
10" W.C.
Natural
4" W.C.
Propane
10" W.C.
Natural
4" W.C.
Propane
10" W.C.
Party Approvals:
rd
Conforms to ANSI STD Z83. 11-2016,
Certified to CSA STD 1.8-2016
Conforms to NSF/ANSI Std.4
5004906
Height (in)
Gas Connection (in)
D
E
F
G
47.2
34.7
6.0
47.2
34.7
6.0
47.2
34.7
6.0
Rate Each
Number
BTUs / Hour
of heat tube
3
3
4
4
5
5
PARTY APPROVALS
RD
H
I
7.0
4.2
7.0
4.2
7.0
4.2
Total Rate
BTUs / Hour
30,000
90,000
30,000
90,000
30,000
120,000
30,000
120,000
30,000
150,000
30,000
150,000
Total BTU/hr
90,000
120,000
150,000
Orifice
Size
#40
#52
#40
#52
#40
#52
18