If disconnecting the restraining device is needed for servicing or cleaning the unit,
reconnect the restraining device after the fryer is placed back into its original position.
The fryer must use with an approved restraint cable and quick disconnect gas supply flexible
hose connector complying with all applicable codes.
The fryer set up must have a proven restraining means to prevent transmitting strain to the
restraining connector. [See the above illustration for a better understanding of this requirement.]
The fryer must be installed with the casters provided or approved by its manufacturer.
If the restraint cable is ever to be disconnected, first turn the gas supply off, reconnect the
restraint cable before returning the appliance into normal operation.
LEVELING THE FRYER
Check if the fryer is level by placing a "level" on top of the fryer after all the gas connections have been
made. Ensure that the fryer is level front-to-back and side-to-side in its final installed position.
If using casters, lock the wheels after unit is level and confirm that the fryer will essentially stay level and
stable as it is moved into the various envisioned locations for operation, cleaning and servicing the unit.
(Be careful if moving a full vat as the oil may splash out)
9