Gas Pressure; Testing The Gas Supply Piping Connection; Mobile Fryer Installations - BakeMax BMF40-90NAT Mode D'emploi

Friteuses au gaz à graisse alimentaire
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GAS PRESSURE (ALL MODELS): Natural Gas, Town Gas or LP {Liquid Propane Gas}
The gas pressure must be set at 4" W.C. (Water Column) (0.8 kPa) for natural gas and 10" W.C. (2.75 kPa)
for LP gas. If incoming pressure exceeds ½ PSI (3.45 kPa), an additional pressure regulator must be installed.
{Meeting this requirement is the owner's responsibility} The name plate indicates which form of gas fuel
supply is to be connected to this fryer LP or Natural Gas.
All gas piping should be performed by a licensed plumber and approved by an authorized local building
code and fire protection inspector.

TESTING THE GAS SUPPLY PIPING CONNECTION

 When test pressures exceed ½ PSI (3.45 kPa), the fryer and its individual shutoff valve
must be disconnected from the gas supply piping system.
 When test pressures are ½ PSI (3.45 kPa) or less, the fryer must be isolated from the gas supply
piping system by closing its individual shutoff valve.
If any leaks must be repaired, ensure the line is free of any residual gas and then execute the needed
remedial action safely and properly to conform the prevailing codes and ordinances.
MOBILE FRYER INSTALLATION
Approved casters, the quick disconnect supply hose and a secure restraining device
aren't/may not be supplied with these fryers. A provided set of leveling legs is typical
which allows a stationery safe hook-up with the connection of proper gas piping.
Separate instructions for installing casters are included with each purchased caster kit/set:
 The installation must be made with a connector that complies with the current Standard for
Connectors for Movable Gas Appliances, ANSI Z-21.69 or Connectors for Moveable Gas
Appliances, CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for
Quick-Disconnect Devices for Use with Gas Fuel, ANSI Z-21.41 or Quick-Disconnect Devices for
Use with Gas Fuel, CANI- 6.9.
 When installing a quick disconnect you must also install a means for limiting the movement of
the fryer. This restraining device prevents the gas line or quick disconnect hose from being
strained. The restraining device should be attached to the mounting system/cutout on the
fryer's back panel. {See illustration for location}
 The manufacturer/distributor offers an approved and proven mobile gas appliance installation kit
consisting or proper strength and size casters (2 with brakes), approved quick disconnect hose and
rated restraining cable. Its use maintains the factory equipment warranty – other set ups may
result in that protection being voided
8