Wiring Of The Signal Line Of The Wired Controller; Electric Installation; Ⅳ Rated Working Conditions - Gree GFH 09 EA-K6DNA1B/I Mode D'emploi

Climatiseurs split à conduite
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Unitary Duct Split Unitary Duct Split

17 Wiring of the Signal Line of the Wired Controller

1) Open the cover of the electric box of the indoor unit.
2) Let the signal line go through the rubber ring.
3) Insert the signal line to the four-pin socket on the printed circuit board of the
indoor unit.
4) Fix the signal line with the binding wire.

18 Electric Installation

Indoor Unit
Type
Model
GFH(09)EA-K6DNA1B/I
GFH(12)EA-K6DNA1B/I
Cooling
and
GFH(18)EA-K6DNA1B/I
Heating
GFH(21)EA-K6DNA1B/I
GFH(24)EA-K6DNA1B/I
Notes:
The sectional area listed above is applicable to the power cord with at most a
length of 15 meters. For the longer cord, its sectional area should be enlarged to avoid
the cord burning out caused by the over-current.
Ⅳ Rated Working Conditions
Dry bulb temp. ℃
Rated Cooling
Max. cooling
Min. cooling
Rated Heating
Max. heating
Min. heating
Table 7
Power Cord
220-240V~
50Hz
220-240V~
50Hz
220-240V~
50Hz
220-240V~
50Hz
220-240V~
50Hz
Table 8 Working Temperature Range
Indoor side state
Wet bulb temp. ℃
27
19
32
23
21
15
20
15
27
20
15
Running
Current
Input Power(W)
(A)
Indoor
Fan
Cooling
Motor
0.406
75
0.348
65
0.428
80
0.588
110
0.588
110
Dry bulb temp. ℃
35
48
18
24
-15
19
Recommended
Power Cord
(Sectional
Area× Pieces)
Heating
575
1.0×4
865
1.0×4
1080
1.0×4
1610
1.0×4
1610
1.0×4
Outdoor side stae
Wet bulb temp. ℃
24
26
7
18
-16
6

Publicité

Table des Matières
loading

Table des Matières