Safety Measures - Amprobe VP-700-E Mode D'emploi

Masquer les pouces Voir aussi pour VP-700-E:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
The voltage testers AMPROBE VP-700, VP-
710, VP-720 are characterised by the follow-
ing features:
Constructed in accordance with EN
61243-3, DIN VDE 0682-401
Connectable load (load tester)
DC and AC voltage test up to 690 V
Bright LED display
Two-pole determination of rotary field
direction
Digital LC display (VP-720 only)
Single-pole phase test (VP-710, VP-720
only)
Continuity test (VP-710, VP-720 only)
The integrated vibration function is
activated from approx. 150 V if both
pushbuttons are pressed simultaneous-
ly. (VP-720 only)
Measurement point Illumination by
white LED (VP-710, VP-720 only)
Fixed text probe cover eliminates the
risk of injury (BGV 1, § 35, Transporting
Tools)
IP 64 (DIN VDE 0470, Part 1, EN 60529)
No batteries required (VP-700 only)
After unpacking, check that the instrument
is undamaged. The product package com-
prises:
1 voltage tester VP-700, VP-710 or VP-720
2 batteries 1.5V, IEC LR03
(VP-710 and VP-720 only)
1 set of operating instructions
2 test probe covers

Safety Measures

The voltage testers have been constructed
and tested in accordance with the safety
regulations for voltage testers and have left
the factory in a safe and perfect condition.
To maintain this condition, the user must fol-
low the safety instructions in this manual.
ATTENTION
Danger of electric shock
To avoid an electric shock, observe the
precautions when working with volt-
ages exceeding 120 V (60 V) DC or 50 V
(25 V) eff AC. In accordance with DIN
VDE these values represent the thresh-
old contact voltages (values in brackets
refer to limited ranges, e.g. in agricul-
tural areas).
The voltage tester must not be used
with the battery compartment open
(VP-710 and VP-720 only).
Before using the instrument, ensure
that the test lead and test instrument
are in perfect working order. Look out
e.g. for broken cables or leaking batter-
ies (if applicable).
Hold the instrument and accessories by
the designated grip areas only, the dis-
play elements must not be covered.
Never touch the test probes.
The test instrument may be used only
within
ranges and in low-voltage installations
up to 690 V.
The test instrument may be used only in
the measuring circuit category it has
been designed for!
Before and after use, always check that
the instrument is in perfect working
order (e.g. on a known voltage source).
the
specified
measurement
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Vp-710-eVp-720-e

Table des Matières