Fire-Extinguishing Devices; Pneumatic Diagram - TECO LR400 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

In this way it is possible to prevent that a not specific treatment of the substances contained in these products, or their improper use, or improper
use of their parts may be hazardous to the environment or to human health. Furthermore this helps to recover, recycle and reuse many of the mate-
rials used in these products.
For this purpose the electrical and electronic equipment manufacturers and dealers set up proper collection and treatment systems for these pro-
ducts. At the end of life of your product contact your dealer to have information on the collection arrangements.
When buying this new product your dealer will also inform you of the possibility to return free of charge another end of life equipment as long as it is
of equivalent type and has fulfilled the same functions as the supplied equipment.
A disposal of the product different from what described above will be liable to the penalties prescribed by the national provisions in the country
where the product is disposed of.
We also recommend you to adopt further measures for environment protection: recycle the internal and external packing of the product and properly
dispose of dead batteries (if contained in the product).
With your help the amount of natural resources used to produce electrical and electronic equipment can be reduced, the use of landfills for the
disposal of the products, minimized, and the quality of life improved by preventing that potentially hazardous substances are released into the
environment.

12. FIrE-ExTINgUIshINg dEvICEs

Consult the following table to choose the most suitable fire extinguisher.
Dry materials
Water ... YES
Foam ... YES
Powder ... YES*
CO2 ... YES*
NOTE
YES* can be used if more appropriate fire extinguishing materials are not available or for minor fires.
WARNING
This table contains general instructions to be used as guidelines for users. All the applications of each type of extinguisher must be
obtained from the relevant manufacturer.
13.

PNEUmATIC dIAgrAm

01
03
05
06
50
Electrical equipment
Water ... NO
Foam ... NO
Powder ... YES
CO2 ... YES
04
02
Flammable liquids
Water ... NO
Foam ... YES
Powder ... YES
CO2 ... YES
Scheme description
Nr. Description
01 Compressed air inlet
02 Compressed air distributor
03 Pressure relif valve
04 Compressed air outlet for auxiliry implement
05 Solenoid valve 1
06 Blowing nozzle 1
07 Solenoid valve 2
08 Blowing nozzle 2
07
08

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lr500

Table des Matières