Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Parameters quick guide

F menu: it sets and/or reads the frequencies that can be selected through the terminal board
C
D
ODE
ESCRIPTION
F - 0 0
F - 0 0
F - 0 0
Reference frequency 0
F - 0 0
F - 0 0
F - 0 1
F - 0 1
F - 0 1
F - 0 1
F - 0 1
Reference frequency 1
F - 0 2
F - 0 2
F - 0 2
F - 0 2
F - 0 2
Reference frequency 2
F - 0 3
F - 0 3
F - 0 3
Reference frequency3
F - 0 3
F - 0 3
F-04
/
/
F-05
F-06
/
F-07
/
F - 0 8
F - 0 8
Jogging frequency
F - 0 8
F - 0 8
F - 0 8
C menu:
it sets and executes some controls: to execute them, select value 7 and confirm via E.
C
P
ODE
ERFORMED ACTION
C - 0 0
C - 0 0
C - 0 0
C - 0 0
C - 0 0
Permanent storage of all parameters
Recall of previously stored parameters
C - 0 1
C - 0 1
C - 0 1
C - 0 1
C - 0 1
(the currently used parameters are replaced by the previously stored ones)
C - 0 2
C - 0 2
C - 0 2
C - 0 2
C - 0 2
Recall of the factory-set parameters (the storage depends on the operator's choice)
C - 0 3
C - 0 3
C - 0 3
C - 0 3
C - 0 3
Zero setting of the alarm memory
C - 0 4
C - 0 4
C - 0 4
C - 0 4
C - 0 4
Recall and storage of the parameters contained in the external programming key [from key to Inv.] (*)
C - 0 5
C - 0 5
C - 0 5
C - 0 5
C - 0 5
Storage of the inverter parameters on the external programming key [from Inv. to key]
C - 0 6
C - 0 6
C - 0 6
C - 0 6
C - 0 6
Measure of motor phase resistance and corresponding initialization of parameter P - 12 (page 25) (QUIX_V)(*)
(QUIX_V) : parameter available in the QUIXDrive_V version
Caution: all parameters or part of them can be write-protected through P - 19 parameter;
In case of a non-authorized modification attempt or with a running motor, the following message will be
displayed: Prot
NOTE:
All parameters, which are not listed in the tables, are reserved for future developments; as a
consequence, they must be always set to 0.
P
ARAMETER
VAL
P - 1 9
P - 1 9
P - 1 9
P - 1 9
P - 1 9
0 no protection
P - 1 9
P - 1 9
P - 1 9
P - 1 9
P - 1 9
1 F non-protected parameters, the others are protected
P - 1 9
P - 1 9
P - 1 9
P - 1 9
P - 1 9
2 all parameters are protected
P - 1 9
P - 1 9
P - 1 9
P - 1 9
P - 1 9
3 no protection; storage possibility with running motor too; not recommended
NOTE: The sign (*) means that the controls can not be executed with running motor
For safety reasons the P parameters, which can be changed, are divided into three groups or levels. Whether the parameters of
a given level (accessibility) can be changed or not depends on the presetting of the P-20 parameter:
P-20=1
P-20=2
P-20=3
Prot. . . . .
Prot
Prot
Prot
P
ERFORMED ACTION
1st level (factory setting)
2nd level
3rd level
—————— QUIXDrive Inverter ——————
R
U
ANGE
NIT
0.0 / 480.0
0.1 Hz
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
INVERTER PARAMETERS
P
P
RESET VALUE
AGE
0.0
22
"
"
"
"
"
"
"
"
"
1.0
24
(*)
(*)
(*)
17-GB

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Quixdrive v

Table des Matières