After a period without use, or on first use at the beginning of a season:
* After replacing the tank in the heater, wait 4 to 5 minutes before turning on .
* During ignition, it is possible for the varnish and the paint to become hot and
thus to cause some smoke or a slight odour. This situation is quite normal. Just
ventilate the room for a while.
* The heater may not ignite the first time if there is some air in the combustion
system. The ignition procedure should then be repeated once or twice.
* On first ignition, smoke or odour may occur, and the flame may become tem-
porarily larger due to air mixed in the fuel feed pipe. This is quite normal.
* Pre heating time may be longer than usual.

5) Flame Condition

When the unit is lit check the condition of the
flame through the inspection window.
If the condition of the flame is abnormal,
consult your dealer.
Normal flame:
Blue flame with a slight yellow.
Abnormal flame 1:
Flame shrinking. Produces noise or smell and
eventually extinguishes.
Abnormal flame 2:
Yellow flame surrounds the burner.
SLIGHT
YELLOW
BLUE
SHRUNKEN FLAME
YELLOW
51