8. SAFETY DEVICES
The unit will not automatically switch on after dealing with an Error, triggered by
a Safety device. It must be switched On again, to resume use.
AUTO SHUT-OFF DEVICE
A sudden movement or strong impact triggers this system. The system is
automatically reset when the unit is correctly re-positioned. Check and if
necessary eliminate the cause, and then regnite the unit.
PREVENTION OF INCOMPLETE COMBUSTION
A shortage of oxygen, due, for example, to using the Unit for a long time without
ventilating the room, or because of a dirty air filter, triggers this system, in order to
switch off the burner, to prevent the unit from burning abnormally. Make sure that
your room is ventilated at least once or twice per hour, and that the air filter is
cleaned. This system extinguishes the burner, and warns the user that the room is
improperly ventilated.
Whenever any of these safety systems is triggered, ventilate the room and check
and eliminate the cause, and then reignite.
SAFE IGNITION SYSTEM AND FLAME CONDITION MONITOR
This system stops the fuel supply to the burner if there is a danger of the unit catching
fire. If the cause can not be corrected, contact your local dealer.
AUTOMATIC-POWER FAILURE SAFETY DEVICE
In case of power failure or the plug becoming disconnected from the socket, this
system protects the unit from any possibility of abnormal combustion resulting.
When the power is restored , switch on again.
OVERHEATING PREVENTION SYSTEM
If warm air outlet and warm air intake systems are blocked ,or if the space heater
front panel is obstructed, the unit automatically switches off. Eliminate the cause of
overheating, wait until the inside of heater cools and re-ignite.
WARNING if the power cord needs replacing.
In case of damage , the power cord must only be replaced by a repairer recommended by
the manufacturer (or distributor) -some special tools are required.
56