Safety
DE
3.3
Residual Risks
US
3.3.1 Explosion Hazard
FR
Explosion hazards cannot be entirely eliminated in hazardous areas.
IT
ES
▶
Perform all activities in hazardous areas with the utmost care at all times!
RU
Possible hazards ("residual risks") can be categorized according to their cause:
NL
DK
Damage to the device
The device may be warped, dented or scratched during transport, mounting or
SE
commissioning. This can cause it to no longer be sealed. A damaged seal can render the
FI
device's explosion protection partially or completely ineffective.
PT
This may result in explosions causing serious or fatal injuries to persons.
To prevent this, comply with the following safety measures:
GR
▶
Transport the device only in its original packaging or in equivalent packaging.
PL
▶
Check the packaging and the device for damage. Report any damage to R. STAHL
immediately.
CZ
▶
Store the device in its original packaging in a dry place (with no condensation),
SK
and make sure that it is stable and protected against the effects of vibrations and knocks.
HU
Too much heating or electrostatic charge
SL
A subsequent conversion or painting can change the state of the device in such a way
RO
that it is no longer explosion-protected. Improper cleaning can also cause the device to heat
BG
up severely or become electrostatically charged. This can cause sparks. This may result in
explosions causing serious or fatal injuries to persons. To prevent this, comply with the
LV
following safety measures:
LT
▶
Commission the device within the prescribed operating conditions only
EE
(see the label on the device and the "Technical data" chapter).
CH
Damaged seal (impairment of IP protection)
KR
The IP degree of protection identifies how equipment must be sealed according to
regulations.
CN
Making structural modifications, for example drilled holes, or improper mounting can impair
the device's IP protection. This may result in explosions causing serious or fatal injuries to
persons.
▶
Only make modifications to the device in accordance with the directions in these operating
instructions. Have R. STAHL or a certified test body (third-party inspection)
carry out acceptance testing on any modifications made.
▶
Perform maintenance and repairs on the device only using original spare parts.
Consult R. STAHL beforehand.
6
LED illuminated pushbutton
for panel mounting
Series 8018/3
290432 / 8018607300
2021-06-11·IO00·III·en·00