FINISHING THE MOTOR INSTALLATION
NOTE: Before continuing, make sure the power is disconnected by turning off
the circuit breaker or removing the fuse at the circuit box.
Mounting Plate
Fig. 10
Step 1: Remove one of the three screws from the mounting plate and keep for
later use. Loosen the other two (do not remove). (Fig.10 )
Step 2: Release the motor assembly from the J hook, raise the motor
assembly up to the mounting plate, align the slot holes on the mounting plate
Mounting Plate
cover with two loosen screws on the mounting plate. Rotate the mounting
plate cover until two loosened screws lock in place at the narrow end of key
holes. Re-install the screw removed on step 1, tighten three screws securely.
(Fig. 11)
Mounting Plate Cover
Fig. 11
10 | KICHLER.COM